Installation of this unit
Power supply installation
44
There are the following two types of DC cable. Connect each
to the specified terminals on the power source.
≥
DC cable for +24 V
DATA ARCHIVER Module:
Bottom Module
Connection
terminals
Connector
≥
DC cable for +24 V/+12 V
DATA ARCHIVER Module:
Base Module, Extension
Module (with the Writer Unit)
Connection
terminals
Connector
1
Connect the DC cable.
≥
Connect the Bottom Module and the power supply
using the DC cable for
i
24 V.
≥
Connect the Base Module and the Extension Modules
(with the Writer Unit) to the power supply using the DC
cable for
i
24 V/
i
12 V.
Connecting the DC cable
+24V
GND
A
24 V power source
i
terminal
B
24 V power source
j
terminal
White triangle pointing down
GND+12V
GND
+24V
A
24 V power source
i
terminal
B
24 V power source
j
terminal
C
12 V power source
i
terminal
D
12 V power source
j
terminal
White triangle pointing to the right
Important:
Before connecting, check which shelf racks
the 12 V and 24 V power sources have been installed in.
You can see which, 12 V or 24 V, by looking at the model
number shown on the front of the shelf rack (front of the
power supply unit inserted).
12 V
24 V
To the Bottom Module
To the Base
Module and
Extension Module
(with Writer Unit)
Do not mistake
polarities.
12 V: HFE1600-12/S
24 V: HFE1600-24/S