background image

2

Counter

LC2H 

Preset Counter

RoHS compliance 

Features

Half-size body 

(24 x 48 mm 

0.945 × 1.890 in

)  

equipped with the preset 

function

• Preset function equipped in half size

(24 × 48 mm 

0.945 × 1.890 in

)

• 7-segment LCD with backlight for fantastic

visibility

The backlight is switchable between green and red and the display can 
be 

switched between lighting and flashing illumination when counting up

• 8.7 mm 

0.343 in

 Letter Height

(Number of digits: 8 digits)

• Counting Speed Switchable between 30 Hz and

5 kHz

• IP66 compliant for resistance against negative

environmental influences

(only when panel surface uses rubber packing)

• Includes reassuring lock mode and lock switch

to prevent erroneous operation

• Screw terminals are constructed to protect

fingers to ensure safety

IP66

Mode selectable

PRODUCT TYPES

No. digits

Counting 

speed

Output mode

Output

Operating 

voltage

Model No.

8 digits

30 Hz/

5 kHz

switchable

• Output maintain/hold count

• Output maintain/over count

• One shot/over count

• One shot/recount

Tr (1a)

24 V DC

LC2HP-FEW-B-DC24V

Options

Mounting frame

Use for waterproofing 

(front panel surface)

ATH3803

Rubber gasket

ATH3804

Note: Mounting frame and rubber gasket are not included.

CHANGING THE PRESET VALUE

It is possible to change the preset value even during counting. However, be aware of the following 

points.

• If the preset value is changed to less than the count value with counting set to the addition direction, counting will

continue until it reaches full scale, returns to "0 (zero)", and then reaches the new preset value. If the preset value is
changed to a value above the count value, counting will continue until the count value reaches the new preset value.

• Suppose that the counter is preset to count down. Whether a preset count down value is smaller or larger than the count

value, the counter counts down to "0 (zero)".

If the preset value is changed to"0 (zero)", the counter will not complete count-up. It starts 

counting up when the counting value comes to "0 (zero)" again.

• Addition (up-count) input when counting is set to the addition direction, counting will continue until full scale is reached,

return to "0 (zero)" and then complete count-up.

• Subtraction (down-count) input when counting is set to the subtraction direction, counting will continue until full scale

"-9999999" is reached, and then the display will change to “

”.

* Refer to our website for details of product.