LIQI
Page 2
Pr0.03
Range
Default
Unit
0 – 31
1
-
Pr0.04 Inertia Ratio
Range
Default
Unit
0 – 10000
250
%
Pr0.06*
Range
Default
Unit
0 – 1
0
-
Pr0.07* Command pulse input mode setup
Range
Default
Unit
0 – 3
1
-
0 or 2 : 2-phase input (AB phase)
1 : CW – CCW
3 : Pulse + Direction
Pr0.08*
Range
Default
Unit
0 – 20 Bit
10000
Pulses
Pr0.09
Range
Default
Unit
0
-
Pr0.10 Denominator of electronic gear
Range
Default
Unit
10000
-
Pr0.11*
Range
Default
Unit
0 – 262144
2500
Pulses
Pr0.12* Reversal of pulse output logic
Range
Default
Unit
0 – 3
0
-
1 or 3 : Reversal
Pr0.13
Range
Default
Unit
0 – 500
300
%
* for more detail please refer Panasonic A5 manual
Selection of machine stiffness at real-
time auto tuning setup
Command pulse rotational direction
setup
Command pulse counts per motor
revolution
1
st
Numerator of electronic gear
0 – 2
30
0 – 2
30
Output pulse counts per motor
revolution
[0]
or 2 : Non reversal
1
st
Torque limit
Summary of Contents for LIQI