– 147 –
Chapter 10 Specifications — Specifications
XPT Unit AV-LSX10
Power supply/Current consumed
<AC IN 1> AC ( ) 100 V to 240 V, 50 Hz/60 Hz, 1.5 A
<AC IN 2> AC ( ) 100 V to 240 V, 50 Hz/60 Hz, 1.5 A
Supports redundant power supply.
Power consumption
150 W
indicates safety information.
Video terminal
<SFP28 A 1> to <SFP28 A 4> terminals
<SFP28 B 1> to <SFP28 B 4> terminals
<SFP28 1> to <SFP28 4> terminals
f
Connectors: SFP28
Used for connecting the Gateway Unit/ME Unit.
f
Mellanox: Use MCP2M00-A001E30N.
Signal formats
During 4K mode: 2160/59.94p, 2160/50p
During Standard mode: 1080/59.94p, 1080/50p, 1080/59.94i, 1080/50i
Signal processing
Y: P
B
: P
R
4: 2: 2 10 bit
<SDI IN 1>, <SDI IN 2> terminals
The SDI IN terminals cannot be used. Do not connect a cable.
<SDI OUT 1>, <SDI OUT 2> terminals
The SDI OUT terminals cannot be used. Do not connect a cable.
Synchronous terminal
<REF> terminal
In Genlock mode: Black burst or Tri-level Sync input signals (with loop-through)
f
If the loop-through output is not used, provide a 75 Ω termination.
f
Connector: BNC
f
Same field frequencies as those of the system formats supported
Control terminal
<LAN1> terminal
Compatible with 1000BASE-T and AUTO-MDIX (For IP control)
f
Connection cable: LAN cable (CAT5E), max. 100 m (328 ft), STP (Shielded Twisted Pair cable recommended)
f
Connector: RJ-45
<LAN2> terminal
For a future expansion feature.
Do not connect a cable.
Other
Ambient operating temperature
0 °C to 40 °C (32 °F to 104 °F)
Humidity
10% to 90% (no condensation)
Dimensions (W
×
H
×
D)
432 mm
×
44 mm
×
402 mm (17 inches
×
1-23/32 inches
×
15-13/16 inches) (excluding protrusions)
Mass
Approx. 6.5 k
]
(14.3 lbs.)
Summary of Contents for Live Production Suite Series
Page 5: ...Please read this chapter and check the accessories before use Chapter 1 Overview ...
Page 11: ...This chapter describes installation and connection Chapter 2 Installation and Connection ...
Page 50: ...This chapter describes menu operations Chapter 5 Basic Operations ...
Page 113: ...This chapter describes the configuration of operations Chapter 7 Configuring Operations ...
Page 122: ...This chapter describes how to operate system menus Chapter 8 System Menu ...
Page 136: ...This chapter describes plug in functions Chapter 9 External Interfaces ...
Page 140: ... 140 Chapter 10 Specifications Dimensions Dimensions of the XPT Unit AV LSX10 Unit mm inch ...
Page 141: ... 141 Chapter 10 Specifications Dimensions Dimensions of the ME Unit AV LSM10 Unit mm inch ...
Page 153: ...This chapter describes the setting menu table and terms Chapter 11 Appendix ...
Page 176: ...Web Site https www panasonic com Panasonic Corporation 2020 ...