176
Description
6
X/Y Offset :
Shifts the object to X/Y direction. This coordinate is applied to the origin of the base object.
Setting Range
-45.000 to +45.000 mm
(LP-V10)
-55.000 to +55.000 mm
(LP-430 / LP-420 / LP-410)
-80.000 to +80.000 mm
(LP-435 / LP-425 / LP-V15)
-27.500 to +27.500 mm
(LP-431 / LP-421 / LP-411 / LP-W052)
7
Count up / down at each step :
Check this box to validate the counter updating at each marking of Step & Repeat.
Reference
•
Counter marking is impossible unless the functional character for counter has been input in the character string for
marking.
•
In case the counter is included in the marking character and the “Count up/down at each step” is not selected, the all
counter values are the same in one Step & Repeat marking as shown in the figure below.
1
1
1
1
1
1
1
1
1
2
2
2
2
2
2
2
2
2
3
3
3
3
3
3
3
3
3
4
4
4
4
4
4
4
4
4
8
Count “Mark OFF” :
When the Step & Repeat counter is used and set the mark off in the specified pattern, select here whether the
counter value of the marking off part is counted or skipped.
Refer to “Step & Repeat Fine-Adjustment” (P.178).
Yes
: Skips counter value on the column/row which “Mark OFF”.
(ex) Step-Repeat with 3 rows × 3 columns
Marking OFF: marking on the 2nd row of 2nd line
Direction: Hori.
Starting Position: Upper L
1
4
7
2
8
3
6
9
No
: Not skip counter value on the column/row which “Mark OFF”.
(ex) Step-Repeat with 3 rows × 3 columns
Marking OFF: marking on the 2nd row of 2nd line
Direction: Hori.
Starting Position: Upper L
1
4
6
2
7
3
5
8
ME-LP400V-OP-6
Summary of Contents for LP-400 Series
Page 11: ...11 MEMO ME LP400V OP 6 ...
Page 32: ...32 1 Product Overview ME LP400V OP 6 ...
Page 58: ...2 Installation and Connection ME LP400V OP 6 ...
Page 77: ...3 Basic Operation Procedure ME LP400V OP 6 ...
Page 121: ...4 Description of Operation Screen ME LP400V OP 6 ...
Page 146: ...146 Symbol ME LP400V OP 6 ...
Page 271: ...271 MEMO ME LP400V OP 6 ...
Page 272: ...Maintenance ME LP400V OP 6 ...
Page 291: ...Troubleshooting ME LP400V OP 6 ...
Page 308: ...Appendix ME LP400V OP 6 ...
Page 328: ...Index ME LP400V OP 6 ...
Page 333: ...No 9000 0062 14V ...
Page 334: ... Panasonic Industrial Devices SUNX Co Ltd 2003 2018 July 2018 9000 0062 14V ...