223
(2) Equidistant Marking
Marking is repeated every time the line moves with the interval set in equidistant marking.
Equidistant marking is performed while the marking trigger is turned to ON.
Reference
• Equidistant marking on the flying object cannot be used in combination with rank marking, external offset, and serial
data marking function.
When the encoder is not used
(Encoder signal: invalid)
When the encoder is used
(Encoder signal: valid)
1
3
2
4
1
5
6
4
Description
1
Interval (Marking Interval)
Inputs the moving distance of the line for marking start.
Setting Range
0 to 3000.0mm
2
Line Speed
Inputs the line speed. Available when encoder setting is disabled.
Setting Range
0.060 to 240.000 m/min (LP-430 / LP-420 / LP-435 / LP-425 / LP-V10 / LP-V15)
0.060 to 170.000 m/min
(LP-410)
0.060 to 120.000 m/min
(LP-431 / LP-421 / LP-W052)
0.060 to 85.000 m/min
(LP-411)
3
Delay Distance
Inputs the moving distance of line from trigger input to the start of marking.
Setting Range
0 to 500.00mm
A
A
A
Delay Distance
Marking Trigger ON
Moving Direction
Sensor
Marking Interval
Marking Interval
Reference
•
Set a delay distance shorter than a marking interval.
ME-LP400V-OP-6
Summary of Contents for LP-400 Series
Page 11: ...11 MEMO ME LP400V OP 6 ...
Page 32: ...32 1 Product Overview ME LP400V OP 6 ...
Page 58: ...2 Installation and Connection ME LP400V OP 6 ...
Page 77: ...3 Basic Operation Procedure ME LP400V OP 6 ...
Page 121: ...4 Description of Operation Screen ME LP400V OP 6 ...
Page 146: ...146 Symbol ME LP400V OP 6 ...
Page 271: ...271 MEMO ME LP400V OP 6 ...
Page 272: ...Maintenance ME LP400V OP 6 ...
Page 291: ...Troubleshooting ME LP400V OP 6 ...
Page 308: ...Appendix ME LP400V OP 6 ...
Page 328: ...Index ME LP400V OP 6 ...
Page 333: ...No 9000 0062 14V ...
Page 334: ... Panasonic Industrial Devices SUNX Co Ltd 2003 2018 July 2018 9000 0062 14V ...