311
CODE128
Bar Code Symbol (entire width of bar code)
6. Bar Code Height
3. Data Character
5. Check Character
2. Start Character
2. Stop Character
1. Quiet Zone
1. Quiet Zone
Name
Description
1
Quiet Zone
Certain spacing is necessary for the back and forth to scan the barcode.
2
Start/Stop Character
The particular characters to indicate the start and end of the bar code.
CODE128 has three types of start code (A, B, and C) and one stop code.
Depending on the start character, the character code set is defined as “Code A”, “Code B”
or “Code C”.
The code set is determined by data character contents.
The laser marker automatically selects the code set according to the input data.
3
Data Character
On CODE128 bar code, a character consists of 11 modules (minimum unit consisting of
bars and spaces). It has four types of element width from 1 to 4 modules.
4
Function Character
Entering “FNC1” just before the data characters indicates that the code is UCC/EAN128
(GS1-128).
5
Check Character
Used to check if the read data is correct or not by putting the value calculated with the
certain formula (modulus 103) on just before the stop character for re-calculation.
6
Bar Code Height
Usually 5 mm or 15% of the symbol width excluding the quiet zone, whichever is greater.
Content of code data
•
The CODE128 bar code can indicate 128 characters of ASCII code consisting of numerical characters, alphanumerical
characters (capitals and small letters), symbols and control code.
ME-LP400V-OP-6
Summary of Contents for LP-400 Series
Page 11: ...11 MEMO ME LP400V OP 6 ...
Page 32: ...32 1 Product Overview ME LP400V OP 6 ...
Page 58: ...2 Installation and Connection ME LP400V OP 6 ...
Page 77: ...3 Basic Operation Procedure ME LP400V OP 6 ...
Page 121: ...4 Description of Operation Screen ME LP400V OP 6 ...
Page 146: ...146 Symbol ME LP400V OP 6 ...
Page 271: ...271 MEMO ME LP400V OP 6 ...
Page 272: ...Maintenance ME LP400V OP 6 ...
Page 291: ...Troubleshooting ME LP400V OP 6 ...
Page 308: ...Appendix ME LP400V OP 6 ...
Page 328: ...Index ME LP400V OP 6 ...
Page 333: ...No 9000 0062 14V ...
Page 334: ... Panasonic Industrial Devices SUNX Co Ltd 2003 2018 July 2018 9000 0062 14V ...