59
2-1 Installation
2-1-1 Installation Environment
Use this product in the following environments.
Item
Installation environment conditions
Operating Ambient Temperature *1
0°C to +40°C
Operating Ambient Humidity *1
35 to 85%RH
Ambient Temperature for Storage *1
-10°C to +60°C *2
Use location
Indoor; at an altitude of 1000 m or below
*1 : No condensation or freezing shall be allowed.
*2 : If there is a gap between the stored temperature and operating temperature, make sure to have the product get used
to the operating ambient temperature gradually prior to use to prevent the dew condensation.
Notice
•
Do not install the laser marker at a place where vibrations and shocks can be directly transmitted to it.
•
Do not incorporate the laser marker in a unit where the laser head will be moved. It may cause failure.
•
Do not use the laser marker at a place with a lot of oil mist and/or dust. Take measures to prevent oil contents and dust
from entering into the laser marker, e.g. using a storage box.
⿎
Installation environment for the stable operation
For the stable operation, install the laser marker with an appropriate protection measures as follows according to the usage
environment.
•
Protection in a dusty place
If the laser marker is installed at a dusty and/or oil-mist-laden place, it could cause malfunction of the product. Take a
measures to protect the laser marker from penetration of the contamination, such as placing the head and the controller
in the dust and/or oil protective enclosure.
Besides, clean or replace the filters regularly in accordance with the usage conditions.
Example of a storage box:
According to the ambient temperature, use a storage box equipped with panel cooler or heat exchanger to maintain the
air-cooling performance of the laser marker.
Panel Cooler
or
Heat Exchanger
WARNING
•
If the laser emission indicator on the laser marker is placed out of the sight of
operators, place the external indicator light or warning lamp on the immediately
apparent place on the system.
ME-LP400V-OP-6
Summary of Contents for LP-400 Series
Page 11: ...11 MEMO ME LP400V OP 6 ...
Page 32: ...32 1 Product Overview ME LP400V OP 6 ...
Page 58: ...2 Installation and Connection ME LP400V OP 6 ...
Page 77: ...3 Basic Operation Procedure ME LP400V OP 6 ...
Page 121: ...4 Description of Operation Screen ME LP400V OP 6 ...
Page 146: ...146 Symbol ME LP400V OP 6 ...
Page 271: ...271 MEMO ME LP400V OP 6 ...
Page 272: ...Maintenance ME LP400V OP 6 ...
Page 291: ...Troubleshooting ME LP400V OP 6 ...
Page 308: ...Appendix ME LP400V OP 6 ...
Page 328: ...Index ME LP400V OP 6 ...
Page 333: ...No 9000 0062 14V ...
Page 334: ... Panasonic Industrial Devices SUNX Co Ltd 2003 2018 July 2018 9000 0062 14V ...