135
⿎
Flying object wait : MWT
Sets the waiting time for marking corresponding to the line speed for flying object marking.
• Setting / Readout data of flying object wait
STX
MWT
Sub
command
[Flying object wait]
6-byte
(Check
sum)
Delimiter
Sub command is “S” at the time of setting and “A” for response data at the time of readout.
• Readout request of flying object wait
STX
MWT
R
(Check sum)
Delimiter
Name
Data
length
[byte]
Description
Remarks
Flying object wait
6
“000.00”–“500.00” [ms]
Available only when the moving direction of marking
object is other than “still”.
⿎
Line speed : LSP
Sets the line speed in flying object marking.
•
Setting / Readout data of line speed
STX
LSP
Sub
command
[Line speed]
7-byte
(Check
sum)
Delimiter
Sub command is “S” at the time of setting and “A” for response data at the time of readout.
•
Readout request of line speed
STX
LSP
R
(Check sum)
Delimiter
Name
Data
length
[byte]
Description
Remarks
Line speed
7
Model type*
Setting range [m/min.]
LP-V10/LP-V15/
LP-430/LP-435/
LP-420/LP-425
“000.060”–“240.000”
LP-W/LP-431/
LP-421
“000.060”–“120.000”
LP-410
“000.060”–“170.000”
LP-411
“000.060”–“085.000”
The speed with which the object to be
marked passes is indicated, available
only when the traveling direction is
other than “still” and encoder signal is
“OFF”.
* For the detail of the model type, refer to “Target laser marker” (P.8).
ME-LP400V-EX-6
Summary of Contents for LP-400 Series
Page 12: ...1 Before External Control ME LP400V EX 6...
Page 24: ...2 Control by I O ME LP400V EX 6...
Page 56: ...3 Control by Serial Communication RS 232 Ethernet ME LP400V EX 6...
Page 141: ...Troubleshooting ME LP400V EX 6...
Page 158: ...Character Code Table ME LP400V EX 6...
Page 176: ...Index ME LP400V EX 6...
Page 179: ...No 9000 0062 17V...
Page 180: ...Panasonic Industrial Devices SUNX Co Ltd 2003 2018 July 2018 9000 0062 17V...