150
Troubles
Causes
Measures
The sending command is
not accepted by the laser
marker. (NAK response)
DIP switch No. 2 on back of laser
marker is off.
To control the following commands with the serial
communication, turn ON DIP switch No. 2.
•
Laser Control [LSR]
•
Shutter Control [SHT]
•
Laser Check Radiation [SPT]
•
Guide LD Indication [GID]
•
Power Check [PWR]
“Reception mode ON” is not set for
command reception permission (MKM
command)
The laser marker does not accept commands
except the following unless it is in the “reception
mode ON” status.
For command transmission, set “reception mode
ON” for “command reception permission (MKM
command)”.
• File Change (No. Specified) [FNO]
• File Change (Comment Specified) [FNN]
•
Shutter Control [SHT]
•
Command Reception Permission [MKM]
•
Laser Control [LSR]
•
Counter Reset [CTR]
•
Status Request [STS]
•
Marking Trigger [MRK]
•
Serial Data Input [SIN]
•
Error code [ECR]
Alarm or error occurs.
All commands except the following are refused
while alarm or error is active.
•
When alarm occurred:
•
Status Request [STS]
•
Error code [ECR]
•
When warning occurred:
•
Status Request [STS]
•
Error code [ECR]
•
Shutter control [SHT] (for closing motion
only)
•
Command Reception Permission [MKM]
(Only for reception mode ON and reception
mode readout)
Two or more command data are
transmitted at the same time.
After sending the command, confirm the response
data from the laser marker. Do not send the next
command before receiving the response.
Others
Troubles
Causes
Measures
Laser is emitted at
unintended timing.
Photoelectric sensor for marking trigger
signal malfunctions.
Fumes may cause malfunction of photoelectric
sensor for marking trigger signal.
•
Install dust collector.
•
Check that dust collector works well.
Date is reset.
Internal battery has run out.
Contact failure may also be a cause of this
symptom. When laser marker have been in use
for five years or more, internal battery is easy to
run out.
Contact our sales office for replacement of
internal battery.
ME-LP400V-EX-6
Summary of Contents for LP-400 Series
Page 12: ...1 Before External Control ME LP400V EX 6...
Page 24: ...2 Control by I O ME LP400V EX 6...
Page 56: ...3 Control by Serial Communication RS 232 Ethernet ME LP400V EX 6...
Page 141: ...Troubleshooting ME LP400V EX 6...
Page 158: ...Character Code Table ME LP400V EX 6...
Page 176: ...Index ME LP400V EX 6...
Page 179: ...No 9000 0062 17V...
Page 180: ...Panasonic Industrial Devices SUNX Co Ltd 2003 2018 July 2018 9000 0062 17V...