154
Warning
Errors that notify of that the setting data are incorrect or laser radiation conditions are not met are output as warnings.
Marking operation cannot be started while any warning is active. Laser pumping maintains the state before the warning.
Release method of warning
1)
Remove a cause of warning. If the warning cause is the wrong setting, correct the file data.
2) When the laser marker is under the remote mode, close the shutter by I/O or serial communication control.
In case of the following warning, the shutter control is unnecessary.
• E800: the warning occurs only while the specified one-shot output time and it is released automatically.
•
E811: the warning occurs only during the laser stop is opened, and then it is released automatically when the laser
stop is closed.
3)
If the warning occurs during the marking operation of the files in which the counter function is set, check if the counter
value is correct before restart the marking operation.
4) In case that marking is executed again, make sure that the warning output is turned on, and then open the internal
shutter.
ERROR
CODE
Error details
Measures
E251
Detected a decrease in clock battery voltage. Reset
present time.
Contact to our sales office.
While laser Marker power is on, reset “Present Time”
in Environment Setting. When the power is off, reset
“Present Time”.
E500
There is not enough free space.
The file cannot be registered.
Delete registered file and logo file.
E501
Cannot register setting because of memory error.
•
Restart with key switch.
• When not recovered, contact our sales office.
E502
E503
Invalid file format of font or logo file.
• Register the logo or font file again on the USB
screen.
• For the logo file, convert the logo data to VEC
format again with Logo data conversion software.
E600
No setting file.
Set the marking data such as character, barcode and
logo.
E601
No font file.
• Register font file.
•
Set a registered font to the font in character
condition.
E602
Lack of font memory.
Make font file smaller, or delete unnecessary font file.
E603
No logo file.
Register logo file.
E604
Included character not registered into font file.
Change characters.
Or set the font file containing the setting characters.
E605
Exceed valid number of characters.
(Max. 30 characters/line.)
Make numbers of characters smaller.
ME-LP400V-EX-6
Summary of Contents for LP-400 Series
Page 12: ...1 Before External Control ME LP400V EX 6...
Page 24: ...2 Control by I O ME LP400V EX 6...
Page 56: ...3 Control by Serial Communication RS 232 Ethernet ME LP400V EX 6...
Page 141: ...Troubleshooting ME LP400V EX 6...
Page 158: ...Character Code Table ME LP400V EX 6...
Page 176: ...Index ME LP400V EX 6...
Page 179: ...No 9000 0062 17V...
Page 180: ...Panasonic Industrial Devices SUNX Co Ltd 2003 2018 July 2018 9000 0062 17V...