3-6 Communication Command List
Category
Name
Code
Function
Page
O
pe
rat
io
n c
on
tro
l
Command reception
permission
MKM
Controls the reception permission (reception mode
ON/OFF) for setting and readout of communication
commands.
Laser pumping
LSR
Controls the laser pumping ON/OFF.
Shutter
SHT
Controls the internal shutter opening/closing.
Status request
STS
Requires the operation status of laser marker, such as
ready status and error occurrence status.
Marking status sending
permission
MST
Enables automatic response of marking result (e.g.
normal end, and error occurrence, etc.) at the end of
marking.
Marking trigger
MRK
Inputs marking trigger (laser radiation startup trigger).
Guide laser control
GID
Controls radiation of red guide laser for marking
position confirmation.
Fi
le
File change (No. specified)
FNO
Specifies the file No. to change the file.
File change (Comment
specified)
FNN
Specifies the file name (comment) to change the file.
File overwriting registration
FOR
Overwrite and register the file under editing.
File registration
FRG
Register the file under editing to the specified No.
File name
FNM
Sets name (comment) of file under editing.
C
ha
ra
ct
er i
np
ut
Marking character string
(ASCII code specified)
MCS
Sets the marking character string by ASCII code.
(For alphanumeric and symbols only)
Marking character string
(Shift-JIS code specified)
STR
Sets the marking character string by shift-JIS code.
(For characters including KANA, KANJI and function
characters)
Serial data input
SIN
Sets the character string specified for “Serial Data
Function” to change characters for each marking.
Rank condition
RKC
Sets input conditions of “Rank Function” to switch
characters using I/O input.
Rank character string
RKS
Sets character string used for “Rank Function” to
switch characters using I/O input.
ME-LP400V-EX-6
Summary of Contents for LP-400 Series
Page 12: ...1 Before External Control ME LP400V EX 6...
Page 24: ...2 Control by I O ME LP400V EX 6...
Page 56: ...3 Control by Serial Communication RS 232 Ethernet ME LP400V EX 6...
Page 141: ...Troubleshooting ME LP400V EX 6...
Page 158: ...Character Code Table ME LP400V EX 6...
Page 176: ...Index ME LP400V EX 6...
Page 179: ...No 9000 0062 17V...
Page 180: ...Panasonic Industrial Devices SUNX Co Ltd 2003 2018 July 2018 9000 0062 17V...