136
⿎
Encoder signal : ENC
Sets the encoder pulse value for use of the encoder in flying object marking.
•
Setting / Readout data of encoder signal
STX
ENC
Sub
command
[Encoder pulse]
6-byte
(Check
sum)
Delimiter
Sub command is “S” at the time of setting and “A” for response data at the time of readout.
•
Readout request of encoder signal
STX
ENC
R
(Check sum)
Delimiter
Name
Data
length
[byte]
Description
Remarks
Encoder pulse
6
“005.00”–“600.00” [Pulse/mm]
Available only when the moving direction is other
than “still”.
Reference
•
The setting changed by this command is saved without overwriting.
⿎
Laser check radiation : SPT
Controls “Laser Check Radiation” for laser radiation at the center of the marking area.
•
Setting of laser check
STX
SPT
S
[Laser check radiation]
1-byte
(Check
sum)
Delimiter
Name
Data
length
[byte]
Description
Remarks
Laser check
radiation
1
“0”: Stop radiation
“1”: Start radiation
“2”: Stop radiation temporarily
•
The internal shutter is automatically opened
and closed at the time of start and stop of
radiation.
•
“Stop radiation temporarily” refers to the
status stopping radiation with the shutter
opened. Use this state only when restarting
radiation in a while.
•
To restart the radiation after sending “2”
(Stop radiation temporarily), send “1” without
closing the shutter.
Reference
•
This command is available only when the DIP switch No. 2 on the rear side of the controller is ON.
•
You can start the laser radiation only when the laser pumping is completed and the shutter is closed or the “command
reception mode ON” is set by Command reception permission (MKM) command.
•
The laser is radiated at the center position.
•
The laser power can be changed by setting the laser condition.
•
Even without “stop” or “interrupt” command, the laser radiation automatically stops after about one minute and the
shutter is closed.
•
Do not control other operation or setting with “Stop radiation temporarily” status. Laser radiation should be ended with
“Stop radiation” status.
•
Do not execute any other operation during the laser radiation.
ME-LP400V-EX-6
Summary of Contents for LP-400 Series
Page 12: ...1 Before External Control ME LP400V EX 6...
Page 24: ...2 Control by I O ME LP400V EX 6...
Page 56: ...3 Control by Serial Communication RS 232 Ethernet ME LP400V EX 6...
Page 141: ...Troubleshooting ME LP400V EX 6...
Page 158: ...Character Code Table ME LP400V EX 6...
Page 176: ...Index ME LP400V EX 6...
Page 179: ...No 9000 0062 17V...
Page 180: ...Panasonic Industrial Devices SUNX Co Ltd 2003 2018 July 2018 9000 0062 17V...