169
⿎
External control
Troubles
Causes
Measures
Communication with
the external device
cannot start.
Laser marker is not in remote
mode.
• Select the remote mode by following the procedure indicated
in Setup/Maintenance Guide.
• Check if the entering method of the remote mode set in the
system settings screen (I/O or PC software) and the actual
control method are consistent.
• If the entering method of the remote mode is changed in the
system settings screen, restart the laser marker.
The connection with external
devices is inadequate.
• Check connections with external equipment for mis-
connection, disconnection or contact failure due to any loose
connector.
• Check for continuity using tester or the like.
There are noises coming
from surrounding equipment.
Protect laser marker against noises as follows:
• Securely ground the frame ground terminal of laser marker or
surrounding equipment.
• Isolate power and signal lines from each other if they have
been routed in parallel.
• Shield signal line.
• Isolate power supply for laser marker from other equipment.
• Use noise cut transformer to absorb noises from power
supply.
Control by serial
communication fails
The connection of the
communication cable is
incorrect.
• Check the applicable cable type and connecting conditions
described in Setup/Maintenance Guide for proper wiring.
• For RS-232C connection, confirm the wiring of the external
device including the loop back connection.
Communication parameter
settings are incorrect.
• Match communication parameter settings to external
equipment.
• If the Ethernet communication settings or RS-232C usage are
changed, restart the laser marker.
• When using RS-232C, specify the “Flow control” to “None”
at the communication port settings of the external control
device.
The communication setting
was changed at the time of
backup file restoration.
Check the communication setting. If Ethernet is used, check
the IP address, etc. When the backup file is restored, the
communication setting is overwritten by the backup data.
Command data is not
received from external
equipment.
Using commercially available line monitor or protocol analyzer,
check if the external equipment transmits data.
Communication data format
(start code) is inadequate.
Check if the start code specified in laser marker system settings
screen and start code of the transmitted data are consistent.
Communication data format
(end code) is inadequate.
• Check if an end code is placed at the end of the transmitted
data.
• For RS-232C, check if the end code is the value specified in
the laser marker system settings screen.
ME-LPGS-SM-8
Summary of Contents for LP-GS Series
Page 17: ...1 Product Overview ME LPGS SM 8 ...
Page 32: ...2 Laser Marker Installation ME LPGS SM 8 ...
Page 48: ...3 Operation Method ME LPGS SM 8 ...
Page 68: ...4 External Control Using I O ME LPGS SM 8 ...
Page 107: ...5 External Control by Communication Commands ME LPGS SM 8 ...
Page 116: ...6 Link Control with External Devices ME LPGS SM 8 ...
Page 141: ...7 Maintenance ME LPGS SM 8 ...
Page 161: ...161 MEMO ME LPGS SM 8 ...
Page 162: ...Troubleshooting ME LPGS SM 8 ...
Page 186: ...Index ME LPGS SM 8 ...
Page 189: ......
Page 190: ... Panasonic Industrial Devices SUNX Co Ltd 2014 2019 April 2019 ...