184
ERROR
CODE
Description
Measures *1
E686
Any of the following functions that are not
available with the seamless loop setting are
configured.
• Multiple objects
• Object consisting of unclosed line(s)
• Point radiation object
• Step & repeat function
• Deactivate the seamless loop in the laser settings.
• If you want to radiate laser continuously without
any break, set the closed line by setting the start
and end points in the same position.
E699
Some setting fields contain an improper value.
• Overwrite the data again to the selected file
number.
• If the problem persists, save the backup file and
contact our sales office or representatives.
E710 - E711
*2, *3
The head air-cooling fan has stopped.
• Refer to Setup/Maintenance Guide and clean the
fan.
• Check the connection status of the fan connector.
• Replace the fan.
• For LP-RC series, confirm the side covers of the
head are installed properly.
E715 *3
The temperature of the laser oscillator is high.
• Check if the ambient temperature of the
laser marker is not exceeding the range of its
specification.
• Make sure air-cooling fan operates.
• Remove the dust and contamination in the air
intake and exhaust port, and clean the air-cooling
part such as fan and filter.
E750
Invalid trigger signal.
TRIGGER IN was input during trigger
processing.
• Turn ON TRIGGER IN after confirming READY
OUT is ON.
• Do not input the marking trigger while
PROCESSING OUT is ON.
• Check the switch or the sensor connected to
TRIGGER IN of I/O terminal operates properly
without chattering.
• Check wiring of I/O or communication port to the
external control devices.
E751
Invalid trigger signal.
TRIGGER IN was input while READY OUT is
OFF.
E752 *3, *4
TARGET DETECTION IN did not turn ON during
the lasing process.
• Check the marking results before and after the
error.
• Check the connection and control method of the
work detection sensor.
• Set the work detection sensor position so that the
sensor turns ON more than 1ms during marking.
• When you do not use this function, set “Disable” at
X7: TARGET DETECTION IN with Laser Marker
NAVI smart system settings.
E760
• I/O connector terminal No. input was not set
successfully.
• Before setting completion (SET OK OUT) was
output, the set input (SET IN) was input at
least twice.
• Keep SET IN turned ON until SET OK OUT turns
ON.
• To input the No. input again, close the shutter and
reset the previous data.
• Check the connection with the external controller.
• Check the control procedure of the external
control.
ME-LPGS-SM-8
Summary of Contents for LP-GS Series
Page 17: ...1 Product Overview ME LPGS SM 8 ...
Page 32: ...2 Laser Marker Installation ME LPGS SM 8 ...
Page 48: ...3 Operation Method ME LPGS SM 8 ...
Page 68: ...4 External Control Using I O ME LPGS SM 8 ...
Page 107: ...5 External Control by Communication Commands ME LPGS SM 8 ...
Page 116: ...6 Link Control with External Devices ME LPGS SM 8 ...
Page 141: ...7 Maintenance ME LPGS SM 8 ...
Page 161: ...161 MEMO ME LPGS SM 8 ...
Page 162: ...Troubleshooting ME LPGS SM 8 ...
Page 186: ...Index ME LPGS SM 8 ...
Page 189: ......
Page 190: ... Panasonic Industrial Devices SUNX Co Ltd 2014 2019 April 2019 ...