43
4.
Connect the three wires to the terminals.
The signs of “L (black)”, “N (white)” and “PE (GND) (yellow/green)” show in
the cables. Connect each cable to the appropriate terminal.
Screw size: M4
Tightening torque: 1.2N·m
ワㄐㄕㄊㄆ
• Connect the attached AC power cable (AC power supply cable).
• Attached AC power cable varies depending on each model. Please select a
cable compliant with the standards in the country or region where it is used.
5.
Attach the resin cover to the terminal and screw the terminal
cover.
Screw size: M3
Tightening torque: 0.5N·m
6.
Fix the AC power cable with the clamp.
Screw size: M4
Tightening torque: 1.0N·m
ワㄐㄕㄊㄆ
• Locate the AC power cable beside the fan. Locating it in front of the fan
may impair the air-cooling performance, leading to the device failure.
7.
Make sure that the cables and connectors other than the power supply are connected and then
connect the AC power cable to the AC power supply.
Power voltage: 90V to 132V AC or 180V to 264V AC (including ±10% voltage fluctuations; automatic switching)
ワㄐㄕㄊㄆ
• The earth terminal of the AC power cable must be permanently grounded.
• Set each connecting cable away from the device that generates high voltage, power line, and large switching surge as
far as possible. If there may be any noise effect on the power supply, use the noise cut-off transformer.
/
1
3(
L N
ME-LPGS-SM-8
Summary of Contents for LP-GS Series
Page 17: ...1 Product Overview ME LPGS SM 8 ...
Page 32: ...2 Laser Marker Installation ME LPGS SM 8 ...
Page 48: ...3 Operation Method ME LPGS SM 8 ...
Page 68: ...4 External Control Using I O ME LPGS SM 8 ...
Page 107: ...5 External Control by Communication Commands ME LPGS SM 8 ...
Page 116: ...6 Link Control with External Devices ME LPGS SM 8 ...
Page 141: ...7 Maintenance ME LPGS SM 8 ...
Page 161: ...161 MEMO ME LPGS SM 8 ...
Page 162: ...Troubleshooting ME LPGS SM 8 ...
Page 186: ...Index ME LPGS SM 8 ...
Page 189: ......
Page 190: ... Panasonic Industrial Devices SUNX Co Ltd 2014 2019 April 2019 ...