76
No.
Name and description
Y16
Y17
Y18
Y19
INTERLOCK 1 MONITOR: Interlock 1 monitoring
INTERLOCK 1 MONITOR COM.: Interlock 1 monitoring common
INTERLOCK 2 MONITOR: Interlock 2 monitoring
INTERLOCK 2 MONITOR COM.: Interlock 2 monitoring common
INTERLOCK 1 MONITOR (Y16 - Y17) monitors the contact status of INTERLOCK 1 (X16 - X17). INTERLOCK
2 MONITOR (Y18 - Y19) monitors the contact status of INTERLOCK 2 (X18 - X19). For details, refer to “4-4-3
Interlock terminal rating and I/O circuit” (P.87).
State of INTERLOCK terminals
Operation of INTERLOCK MONITOR terminals
X16 - X17: OPEN
Y16 - Y17: CLOSE
X16 - X17: CLOSE (Short-circuited)
Y16 - Y17: OPEN
X18 - X19: OPEN
Y18 - Y19: CLOSE
X18 - X19: CLOSE (Short-circuited)
Y18 - Y19: OPEN
Interlock monitor is switched open and closed with a delay of approx. 20ms with reference to each interlock
input as shown below.
20ms
20ms
INT) - INTERLOCK(-)
(X16 - X17, X18 - X19)
INTERLOCK MONITOR - INTERLOCK MONITOR COM.
(Y16 - Y17, Y18 - Y19)
CLOSE
OPEN
CLOSE
OPEN
Y20
LASING OUT: Laser radiation output
Output ON during laser radiation.
In case the lasing time is shorter than the set one-shot output time, the lasing output remains ON until the
one-shot output time ends. *1
ンㄆㄇㄆㄓㄆㄏㄆ
• Use PROCESSING END OUT (Y11) and PROCESSING FAIL OUT (Y12) for the confirmation of marking
completion.
*1 : Set the output time of the one-shot output on the system settings screen of Laser Marker NAVI smart. The setting
range is 2 to 510ms. The initial setting value is 40ms. One-shot output time has a small margin of error for the setting
value.
ME-LPGS-SM-8
Summary of Contents for LP-GS Series
Page 17: ...1 Product Overview ME LPGS SM 8 ...
Page 32: ...2 Laser Marker Installation ME LPGS SM 8 ...
Page 48: ...3 Operation Method ME LPGS SM 8 ...
Page 68: ...4 External Control Using I O ME LPGS SM 8 ...
Page 107: ...5 External Control by Communication Commands ME LPGS SM 8 ...
Page 116: ...6 Link Control with External Devices ME LPGS SM 8 ...
Page 141: ...7 Maintenance ME LPGS SM 8 ...
Page 161: ...161 MEMO ME LPGS SM 8 ...
Page 162: ...Troubleshooting ME LPGS SM 8 ...
Page 186: ...Index ME LPGS SM 8 ...
Page 189: ......
Page 190: ... Panasonic Industrial Devices SUNX Co Ltd 2014 2019 April 2019 ...