119
⿎
Example of command settings
Condition:
Adjustment No. = 0, Adjustment object = 1, Target row = 2, Target column = 3,
X-movement = 0.1, Y-movement = -0.2, Rotation movement = 0, Laser power correction = 0
• Setting
Transmission data
[STX]
SRA
S
00000.100-000.200
or
00000.100-000.200+000.00+00
[CR]
• Readout
Transmission data
[STX]
SRA
R
00
[CR]
Response data
[STX]
SRA
A
00000.100-000.200+000.00+00
[CR]
ME-LP-GS-SR-COMP-3