57
3-3-2 Laser pumping: LSR
Controls the laser pumping ON/OFF.
⿎
Setting request data / response data for readout
Start
code
LSR
Sub command
[Laser pumping control]
1-byte
(Check sum)
End code
Sub command is “S” for the setting request data and “A” for the response data for readout.
⿎
Readout request data
Start
code
LSR
R
(Check sum)
End code
⿎
Data description
Name
Data length [byte]
Data contents
Remarks
Laser pumping
control
1
“0”: Laser pumping OFF
“1”: Laser pumping ON
Total data
length
1
The data length is fixed.
ンㄆㄇㄆㄓㄆㄏㄆ
• This command is available only when the laser pumping control method is set to “communication commands” by Laser
Marker NAVI smart.
• From sending the laser pumping on request to completion of laser pumping, the following time will be required.
• LP-GS series: about 8 to 15 seconds
• LP-RC series: about 10 seconds
• LP-RF series: about 7 seconds
• LP-RV series: about 1 second
• For LP-RC series, the shutter can be opened after turning on the laser pumping. When the laser pumping is turned to
off, the shutter is closed automatically.
• Response data when reading out this command returns the laser pumping control status. If you want to check the laser
pumping ON/OFF status, use the status checking (STS) command.
• When you turn OFF the laser pumping during marking laser processing (laser radiation), an error occurs and this
interrupts the marking trigger processing.
⿎
Example of command settings
Condition:
Laser pumping control = 1
• Setting
Transmission data
[STX]
LSR
S
1
[CR]
• Readout
Transmission data
[STX]
LSR
R
[CR]
Response data
[STX]
LSR
A
1
[CR]
ME-LP-GS-SR-COMP-3
Summary of Contents for LP-GS Series
Page 11: ...1 Preparation of Command Control ME LP GS SR COMP 3...
Page 26: ...2 Communication Control Basics ME LP GS SR COMP 3...
Page 50: ...3 Data Format for Each Command ME LP GS SR COMP 3...
Page 136: ...136 MEMO ME LP GS SR COMP 3...
Page 137: ...Troubleshooting ME LP GS SR COMP 3...
Page 163: ...Character Code Table ME LP GS SR COMP 3...
Page 176: ...Index ME LP GS SR COMP 3...
Page 178: ...178 W Warning 154 ME LP GS SR COMP 3...
Page 179: ......
Page 180: ...Panasonic Industrial Devices SUNX Co Ltd 2014 2019 April 2019...