3-4-2 File selection by name: FNN
Specifies the file name to change the file.
⿎
Setting request data
Start
code
FNN
S
[File name]
Max. 20-byte
(Check sum)
End code
⿎
Data description
Name
Data length
[byte]
Data contents
Remarks
File name
Min. 1
Max. 20
The number of input characters
allowed is 1 to 20 characters.
Input Method: ASCII code or
Shift JIS code (can be mixed)
• Use the ASCII code to specify one-byte
characters (single byte characters).
• Use the Shift JIS code to specify two-byte
characters (double byte characters).
Total data length
Max. 20
Variable length.
ンㄆㄇㄆㄓㄆㄏㄆ
• Refer to “2-3-5 Character data input method” (P.37) for details on the character input method and character types with
input restrictions.
• Specifies a case-sensitive alphabetical file name.
• If the file name contains both the ASCII code (one-byte characters) and Shift JIS code (two-byte characters), specify
them exactly as they are in the ASCII code and Shift JIS code.
• If the file name contains any characters which belong to the non-supported character code, the file cannot be selected
by the command.
• When two or more of the same file names exists, the file with the smaller number is selected.
• Use the file name (FNM) command when you want to read out the file name currently selected.
• The file change operation turns off the marking trigger ready momentarily.
• Unnamed files (0-byte name) cannot be selected with this command.
• At LP-400/V compatible command mode, you cannot select the file name with more than 21-byte length.
⿎
Example of command settings
Condition:
File name = ABCD
• Setting
Transmission data
[STX]
FNN
S
ABCD
[CR]
ME-LP-GS-SR-COMP-3
Summary of Contents for LP-GS Series
Page 11: ...1 Preparation of Command Control ME LP GS SR COMP 3...
Page 26: ...2 Communication Control Basics ME LP GS SR COMP 3...
Page 50: ...3 Data Format for Each Command ME LP GS SR COMP 3...
Page 136: ...136 MEMO ME LP GS SR COMP 3...
Page 137: ...Troubleshooting ME LP GS SR COMP 3...
Page 163: ...Character Code Table ME LP GS SR COMP 3...
Page 176: ...Index ME LP GS SR COMP 3...
Page 178: ...178 W Warning 154 ME LP GS SR COMP 3...
Page 179: ......
Page 180: ...Panasonic Industrial Devices SUNX Co Ltd 2014 2019 April 2019...