100
3-7-4 Human readable text settings: BRV
Sets the character conditions to mark the character strings of bar code/2D code as the human readable text.
⿎
Setting request data / response data for readout
Start
code
BRV
Sub
command
[Object No.] [Positional offset target]
[Relative X-position] [Relative Y-position]
[Character height] [Character width]
[Character spacing] [Font No.]
[Laser power correction] [Scan speed correction]
[Pulse cycle correction]
( [Linefeed] [Linefeed spacing] )
LP-GS/LP-RC: 54-byte, 47-byte or 46-byte
LP-RF/LP-RV: 57-byte, 50-byte or 49-byte
(Check
sum)
End code
Sub command is “S” for the setting request data and “A” for the response data for readout.
⿎
Readout request data
Start
code
BRV
R
[Object No.] [Positional offset target]
2-byte
(Check sum)
End code
⿎
Data description
Name
(> Name in LP-400/V)
Data length
[byte]
Data contents
Remarks
Object No.
(> Bar code No.)
1
“0”–“7”: Object No. 1100 to 1107
Positional offset
target
1
“1”: Bar code / 2D code / 1D side of the
composite codes
“2”: 2D side of the composite codes
Select to which code the settings
of the relative X-/Y-position are
applied.
Relative X-position
8
“-999.999”–“+999.999” [mm]
• It is the relative position to the
code center.
• Specifies the left lower position
of the first character.
• For the composite codes, the
positions of 1D and 2D side can
be separately specified.
Relative Y-position
8
Character height
7
Model
Setting range [mm]
LP-GS051(-L)
“000.100”–“055.000”
LP-GS052
“000.060”–“030.000”
LP-RC350S
“000.100”–“085.000”
LP-RF200P
LP-RV200P
“000.100”–“090.000”
For the composite codes, the
settings from “character height” are
applied to both 1D and 2D side.
Character width
7
Character spacing
7
Model
Setting range [mm]
LP-GS051(-L)
“000.000”–“055.000”
LP-GS052
“000.000”–“030.000”
LP-RC350S
“000.000”–“085.000”
LP-RF200P
LP-RV200P
“000.000”–“090.000”
Font No.
1
“1”–“9”
ME-LP-GS-SR-COMP-3
Summary of Contents for LP-GS Series
Page 11: ...1 Preparation of Command Control ME LP GS SR COMP 3...
Page 26: ...2 Communication Control Basics ME LP GS SR COMP 3...
Page 50: ...3 Data Format for Each Command ME LP GS SR COMP 3...
Page 136: ...136 MEMO ME LP GS SR COMP 3...
Page 137: ...Troubleshooting ME LP GS SR COMP 3...
Page 163: ...Character Code Table ME LP GS SR COMP 3...
Page 176: ...Index ME LP GS SR COMP 3...
Page 178: ...178 W Warning 154 ME LP GS SR COMP 3...
Page 179: ......
Page 180: ...Panasonic Industrial Devices SUNX Co Ltd 2014 2019 April 2019...