134
3-14 System Settings Command
3-14-1 System clock: YMD
Sets the date and time of the system clock of the laser marker. Functional characters such as the current date/time, expiry
date/time, and lot date/time are marked based on this system clock.
⿎
Setting request data / response data for readout
Start
code
YMD
Sub
command
[Year] [Month] [Date] [Hour] [Minute]
[Second]
14-byte
(Check
sum)
End code
Sub command is “S” for the setting request data and “A” for the response data for readout.
⿎
Readout request data
Start
code
YMD
R
(Check sum)
End code
⿎
Data description
Name
Data length [byte]
Data contents
Remarks
Year
4
“1980”–“2099” [Year]
Month
2
“01”–“12” [Month]
Date
2
“01”–“31” [Day]
Hour
2
“00”–“23” [Hour]
Minute
2
“00”–“59” [Minute]
Second
2
“00”–“59” [Second]
Total data length
14
The data length is fixed.
ンㄆㄇㄆㄓㄆㄏㄆ
• The setting changed by this command is saved in the laser marker without overwriting to the file.
⿎
Example of command settings
Condition:
Year = 2014, Month = 12, Date = 10, Hour = 18, Minute = 45, Second = 00
• Setting
Transmission data
[STX]
YMD
S
20141210184500
[CR]
• Readout
Transmission data
[STX]
YMD
R
[CR]
Response data
[STX]
YMD
A
20141210184500
[CR]
ME-LP-GS-SR-COMP-3
Summary of Contents for LP-GS Series
Page 11: ...1 Preparation of Command Control ME LP GS SR COMP 3...
Page 26: ...2 Communication Control Basics ME LP GS SR COMP 3...
Page 50: ...3 Data Format for Each Command ME LP GS SR COMP 3...
Page 136: ...136 MEMO ME LP GS SR COMP 3...
Page 137: ...Troubleshooting ME LP GS SR COMP 3...
Page 163: ...Character Code Table ME LP GS SR COMP 3...
Page 176: ...Index ME LP GS SR COMP 3...
Page 178: ...178 W Warning 154 ME LP GS SR COMP 3...
Page 179: ......
Page 180: ...Panasonic Industrial Devices SUNX Co Ltd 2014 2019 April 2019...