21
1-3-2 Communication settings (LP-400/V compatible mode)
Item
RS-232C communication settings (LP-400/V compatible mode)
Synchro system
Start-stop method
Communication type
Full-duplex transmission
Baud rate
1200 / 2400 / 4800 / 9600 / 19200 / 38400 / 57600 / 115200 bps (initial setting: 9600 bps)
Data length
8-bit fixed
Parity
None / Even / Odd (initial setting: None)
Stop bits
1-bit / 2-bit (initial setting: 1-bit)
Flow control
None
Check sum
OFF / ON (initial setting: OFF)
End code
CR / CR + LF (initial setting: CR)
Start code
• Setting request data, Readout request data, Response data for readout: STX
• Positive response code: ACK
• Negative response code: NAK
Response data command
Included only in response data for readout
Sub command
• Setting request data: S
• Readout request data: R
• Response data for readout: A
Character code
ASCII code
Encoding for 2-byte
characters
Shift-JIS code
Reception timer
Timeout monitoring ON (10 sec.)
ンㄆㄇㄆㄓㄆㄏㄆ
• For the details of the communication settings, refer to “1-1-3 Settings before external control” (P.14).
ME-LP-GS-SR-COMP-3
Summary of Contents for LP-GS Series
Page 11: ...1 Preparation of Command Control ME LP GS SR COMP 3...
Page 26: ...2 Communication Control Basics ME LP GS SR COMP 3...
Page 50: ...3 Data Format for Each Command ME LP GS SR COMP 3...
Page 136: ...136 MEMO ME LP GS SR COMP 3...
Page 137: ...Troubleshooting ME LP GS SR COMP 3...
Page 163: ...Character Code Table ME LP GS SR COMP 3...
Page 176: ...Index ME LP GS SR COMP 3...
Page 178: ...178 W Warning 154 ME LP GS SR COMP 3...
Page 179: ......
Page 180: ...Panasonic Industrial Devices SUNX Co Ltd 2014 2019 April 2019...