112
5-3 Ethernet
5-3-1 Port specifications and connection
To control the laser marker by Ethernet communication, use an Ethernet port on the controller.
ンㄆㄇㄆㄓㄆㄏㄆ
• The Ethernet port of this product is compatible with both straight cable and cross cable.
• Although the maximum length of cables connecting devices permitted by the standards of Ethernet is 100 m, in order to
prevent communication failure due to noise or breakdown of the device, it is recommended to keep the length to 10 m or
less.
• The Ethernet port can be connected with the following devices simultaneously via a HUB or a router.
• PC configuration software
• External device for communication command control (PLC and PC for control)
• Specific image checker
Rear of controller
On the laser marker controller side
RJ-45 8-pole connector
AUTO-MDIX compatible
Orange LED
Green LED
Light up color
Description
Green
The indicator lights up while connected normally. It blinks during communication.
Orange
Lights up only when the baud rate is 100 megabits/sec.
⿎
LAN cable connection
When you connect a LAN cable to the Ethernet port, attach the ferrite core included to a position as close as possible to
the Ethernet port on the LAN cable controller side.
If the ferrite core diameter is too large for the cable width, fix the ferrite core using a tie band.
Ferrite core
LAN cable
Tie band
Laser marker controller
ME-LPGS-SM-8
Summary of Contents for LP-GS Series
Page 17: ...1 Product Overview ME LPGS SM 8 ...
Page 32: ...2 Laser Marker Installation ME LPGS SM 8 ...
Page 48: ...3 Operation Method ME LPGS SM 8 ...
Page 68: ...4 External Control Using I O ME LPGS SM 8 ...
Page 107: ...5 External Control by Communication Commands ME LPGS SM 8 ...
Page 116: ...6 Link Control with External Devices ME LPGS SM 8 ...
Page 141: ...7 Maintenance ME LPGS SM 8 ...
Page 161: ...161 MEMO ME LPGS SM 8 ...
Page 162: ...Troubleshooting ME LPGS SM 8 ...
Page 186: ...Index ME LPGS SM 8 ...
Page 189: ......
Page 190: ... Panasonic Industrial Devices SUNX Co Ltd 2014 2019 April 2019 ...