186
Description
13 Uniform Spot Mode (only LP-M / LP-Z series) :
To keep a uniform diameter of the laser spot within the marking field, specify this mode. The spot size is adjusted
to the selected plane. The laser spot will have the same diameter in the area between N-plane and the selected
plane. This condition is required for setting when the line width is differed due to the marking place. “F-plane” (Far
plane) is selected as the default setting mode.
Setting Mode
Description
OFF
Sets when not using the uniform mode.
The spot size will be adjusted according to the each coordinate.
N-plane (Near)
By selecting this mode, the spot diameter becomes uniform within the marking field on N-plane (the
shortest work distance).
B-plane (Base)
By selecting this mode, the spot diameter will be adjusted to B-plane (the specification value of the
work distance).
The laser spot will have the same diameter in the area between N-plane and the B-plane.
F-plane (Far)
By selecting this mode, the spot diameter will be adjusted to F-plane (the longest work distance).
The laser spot will have the same diameter in the area between N-plane and the F-plane.
Custom
(LP-M Series Only)
Specify the marking field (X/Y field and Z position), where the laser spot size is kept to be uniform.
The laser spot will have the same diameter in the specified XY field between N-plane and the
specified Z position.
XY Field
Specify the length of X and Y axis for the marking field, in which the laser spot size is kept to be
uniform.
The center position of the XY field is always the center of the original marking field.
Setting Range
0 to 120 mm (LP-M200/M500/MA00)
0 to 220 mm (LP-M205/M505/MA05)
0 to 330 mm (LP-MA06)
Z Position
Specify the Z position to which spot diameter the laser spot size in the specified XY field is
adjusted. The laser spot will have the same diameter in the area between N-plane and the
selected Z position. To specify the N-plane direction from B-plane, input 0 mm to +22 mm. To
specify the F-plane direction from B-plane, input 0 mm to -22 mm.
Setting Range
-22 to +22 mm
Work distance of the each plane
Model
N-plane
B-plane
F-plane
LP-M200/M500/MA00
168 mm
190 mm
212 mm
LP-M205/M505/MA05
198 mm
220 mm
242 mm
LP-MA06
308 mm
330 mm
352 mm
LP-Z130/Z250
165 mm
190 mm
215 mm
LP-Z256
305 mm
330 mm
355 mm
Reference
•
In case of not setting the Uniform Spot mode, the spot diameter on the outer of the center of the coordinate becomes
larger.
•
In case of setting the Uniform Spot mode, the spot diameter becomes thicker because the spot diameter is uniformed
based on the thickest spot diameter on each marking plane.
(The spot diameter becomes larger from N-plane, B-plane, and F-plane in sequence.)
N-plane (Near)
B-plane (Base)
F-plane (Far)
ME-LPMSZ-OP-7
Summary of Contents for LP-M Series
Page 11: ...1 Basic Operation Procedure ME LPMSZ OP 7 ...
Page 76: ...76 MEMO ME LPMSZ OP 7 ...
Page 77: ...2 Description of Operation Screen ME LPMSZ OP 7 ...
Page 102: ...102 Symbol ME LPMSZ OP 7 ...
Page 255: ...Troubleshooting ME LPMSZ OP 7 ...
Page 276: ...Appendix ME LPMSZ OP 7 ...
Page 304: ...Index ME LPMSZ OP 7 ...
Page 307: ...No 9000 0063 56V ...
Page 308: ... Panasonic Industrial Devices SUNX Co Ltd 2013 2019 March 2019 9000 0063 56V ...