2-11-2 Marking Energy Measurement
[Function specific to LP-M series / LP-Sxxx type]
*
This function is not implemented in the LP-Z series / LP-SxxxW type.
This window allows you to measure the marking energy per trigger. This window also allows you to set the upper and lower
limits of the marking energy (mJ) per trigger. A deviation from these limits will cause an alarm to occur. You can detect
erroneous markings due to output power fluctuation by using this feature.
To use this function
•
The marking energy must be 100 mJ or more in order to set the upper/lower limits.
• When moving the laser marker, changing the marking object or marking conditions, confirm the marking energy results
and readjust the upper and lower limits of marking energy.
•
After the installation, replacement or moving laser marker, the marking energy measurement results may change.
• In case of LP-Sxxx type, after the fiber unit is installed or removed, or focus is adjusted (see the “Safety / Setup /
Maintenance Guide”), the marking energy measurement results may change.
•
This function cannot detect the marking errors due to the change of target works or the unit condition.
1
2
3
5
4
Description
1
Measurement Result :
After the test marking, displays the laser energy. If the marking energy measurement exceeds the preset upper
limit, an error message appears.
2
Upper Limit :
Lower Limit :
Sets the upper / lower limit of the marking energy. If the measurement results is out of this limit, warning message
appears.
Setting Range
100 to 999999999 [mJ]
3
AUTO CALC. (Automatic Calculation) :
Automatically calculates the upper/lower limits based on the measurements and set upper/lower limit ratio [%].
Setting Range
0 to 99.9 [%]
Reference
•
Automatic calculation cannot be performed when the marking energy was not measured at test marking.
•
Auto calculation is applied only to the enabled upper / lower limit.
4
Laser Setting:
Set the laser power, scan speed and laser pulse cycle when measuring the marking energy.
5
TEST MARKING :
Starts the test marking and measures marking energy.
ME-LPMSZ-OP-7
Summary of Contents for LP-M Series
Page 11: ...1 Basic Operation Procedure ME LPMSZ OP 7 ...
Page 76: ...76 MEMO ME LPMSZ OP 7 ...
Page 77: ...2 Description of Operation Screen ME LPMSZ OP 7 ...
Page 102: ...102 Symbol ME LPMSZ OP 7 ...
Page 255: ...Troubleshooting ME LPMSZ OP 7 ...
Page 276: ...Appendix ME LPMSZ OP 7 ...
Page 304: ...Index ME LPMSZ OP 7 ...
Page 307: ...No 9000 0063 56V ...
Page 308: ... Panasonic Industrial Devices SUNX Co Ltd 2013 2019 March 2019 9000 0063 56V ...