245
Item
Description
8
Correction Date
: It denotes the date and time when the power is corrected.
9
Power Correction
Ratio
: It shows power correction ratio. Set the ratio so that the current power × power
correction ratio = 100.
10 Laser Rad. Time
(Laser Radiation
Time)
: Displays the total time of the laser radiation.
11 Correction Date
and Time
: It denotes the date and time when the power monitor is corrected.
12 Calibrate power
monitor
: After the installation, replacement or moving of laser marker, the accuracy of the
measurement result may decrease. In that case, perform a power monitor calibration.
When the power monitor calibration is performed, the measurement is shown assuming
the power at that point to be 100%. Refer to “Power Monitor Calibration” (P.246) for the
setting details.
To use this function
•
Power correction refers to the function to correct not the max. laser power [W] value but the laser power setting value.
Power correction cannot increase the output power at the maximum power setting.
•
The measurement results might have +/-5% difference with normal temperature (20 to 30 Celsius degree).
•
The +/-10% difference might occur under the high/low temperature. Correcting power under normal temperature (20 to
30 Celsius degree) is recommended.
• The values shown in “Current Power” and “Corrected Power” fields are the relative value expressed as a percentage to
the initial power of the laser oscillator.
•
Power check function is available when laser pumping is completed.
•
Use “Calibrate power monitor” function to improves the accuracy of “Power Check” results after the installation,
replacement or moving of laser marker.
•
Power monitor calibration cannot be initiated from “Laser Marker NAVI plus”.
ME-LPMSZ-OP-7
Summary of Contents for LP-M Series
Page 11: ...1 Basic Operation Procedure ME LPMSZ OP 7 ...
Page 76: ...76 MEMO ME LPMSZ OP 7 ...
Page 77: ...2 Description of Operation Screen ME LPMSZ OP 7 ...
Page 102: ...102 Symbol ME LPMSZ OP 7 ...
Page 255: ...Troubleshooting ME LPMSZ OP 7 ...
Page 276: ...Appendix ME LPMSZ OP 7 ...
Page 304: ...Index ME LPMSZ OP 7 ...
Page 307: ...No 9000 0063 56V ...
Page 308: ... Panasonic Industrial Devices SUNX Co Ltd 2013 2019 March 2019 9000 0063 56V ...