2-16-7 Adjustment of Touch Panel
Long time use of the touch panel may cause misalignment (of touch panel buttons) due to stress. This section describes
how to calibrate the touch panel.
1.
Use a pen to touch the center of the cross at the
lower left corner.
2.
Use a pen to touch the center of the cross at the
upper right corner.
A message will appear asking you if you want to save the
calibration result.
Notice
•
Lightly touch the center of the cross with a pen whose tip radius is approx. 0.5. An excessive force applied to the touch
panel may damage the panel.
3.
Press [OK].
Pressing [Cancel] or doing nothing for 10 seconds will cancel the
calibration result.
Reference
•
Out of synchronous on console is considered if the displacement of display position on the screen or bleeding of display
occurs.
Adjust the synchronous in accordance with the method described in the instruction manual of console.
ME-LPMSZ-OP-7