94
2-6-3 Test Marking
Test marking is a marking method of radiating laser by the button operations on the setting screen.
1.
Press the laser pumping switch on the controller.
2.
Set the marking mode into [TEST].
3.
The test marking is displayed by pressing
[START].
The marking is started by pressing [OK].
The laser marker is performed the following
procedure.
Press [OK] of the dialog box for test marking.
Internal Shutter: Open
Marking
Internal Shutter: Close
4.
In case of LP-M series and LP-Sxxx type:
When the marking energy is enabled, the marking energy and time
are displayed. Refer to “2-16-4 Laser Output Confirmation” (P.236)
If the marking energy lowers to the predetermined lower limit, alarm
E710 occurs indicating the marking energy is out of order.
See “2-11-2 Marking Energy Measurement” (P.187) for how to set the
upper and lower limits of the marking energy.
Reference
•
The marking energy measurement function is not implemented to LP-Z series and LP-SxxxW type.
•
The counter does not activate at test marking.
•
For LP-Mxxx-S type, laser can not be emitted without opening the laser gate. After starting the test marking, open the
laser gate by external control signals. Refer to the “Safety / Setup / Maintenance Guide” for detail.
WARNING
•
Once starting the test marking, the laser radiation cannot be stopped till the
marking is finished. If the operator needs to stop the laser radiation, use the
interlock system constructed by using the interlock connector on the controller.
ME-LPMSZ-OP-7
Summary of Contents for LP-M Series
Page 11: ...1 Basic Operation Procedure ME LPMSZ OP 7 ...
Page 76: ...76 MEMO ME LPMSZ OP 7 ...
Page 77: ...2 Description of Operation Screen ME LPMSZ OP 7 ...
Page 102: ...102 Symbol ME LPMSZ OP 7 ...
Page 255: ...Troubleshooting ME LPMSZ OP 7 ...
Page 276: ...Appendix ME LPMSZ OP 7 ...
Page 304: ...Index ME LPMSZ OP 7 ...
Page 307: ...No 9000 0063 56V ...
Page 308: ... Panasonic Industrial Devices SUNX Co Ltd 2013 2019 March 2019 9000 0063 56V ...