108
Response to readout designation of power check result
STX
PWR
A
[Current power] [Power after correction]
[Power correction ratio] [Correction date]
[Total laser radiation time] [Determination]
33-byte (LP-SxxxW), 32-byte (LP-Zxxx)
(Check sum)
Delimiter
Name
Data length
[byte]
Content
Remarks
Current power
3
“000”–“xxx”
Indicates the current power ratio [%] in comparison
with the default laser power.
Power after
correction
3
“000”–“xxx”
•
The value obtained by multiplying the current
power by the power correction ratio is indicated.
It may differ from the calculated value depending
on the correction ratio.
•
When the power correction has not been
performed, this value is “000”.
Power
correction ratio
5
“050.0”–“200.0” [%]
When the power correction has not been performed,
this value is “000”.
Correction date
14
For 15:00:00 on April 1, 2012
“20120401150000”
When the power correction has not been performed,
this value is “00000000000000”.
Total laser
radiation time
9
“0000000.0”–“1000000.0” [h]
Determination
(Applicable only
LP-SxxxW)
(1)
“0”: Correct
“1”: Lower than the “Low Power
Detect Level”.
It is indicated whether or not the power check result
is lower than the value set in “Low Power Detect
Level”.
This result is valid only in the measurement result
readout just after the start point of the power check.
(Not transmitted for LP-Zxxx.)
Reference
•
Power correction refers to the function to correct not the max. laser power [W] value but the laser power setting value.
Power correction does not change the actual max. output power relative to initial power.
ME-LPMSZ-SR-9
Summary of Contents for LP-M Series
Page 8: ...1 Before External Control ME LPMSZ SR 9...
Page 16: ...2 Basics of Serial Communication RS 232 Ethernet ME LPMSZ SR 9...
Page 34: ...3 Communication Command and Function ME LPMSZ SR 9...
Page 165: ...Troubleshooting ME LPMSZ SR 9...
Page 186: ...Character Code Table ME LPMSZ SR 9...
Page 199: ...Index ME LPMSZ SR 9...
Page 202: ...202 MEMO No 9000 0063 59V ME LPMSZ SR 9...
Page 203: ...No 9000 0063 59V...
Page 204: ...Panasonic Industrial Devices SUNX Co Ltd 2013 2019 March 2019 9000 0063 59V...