114
■
Year/Month/Date/Time: YMD
Sets year, month, date, time for system.
Setting / Readout data of year/month/date/time
STX
YMD
Sub
command
[Dominical year] [Month] [Day] [Hour] [Minute] [Second]
14-byte
(Check sum)
Delimiter
Sub command is “S” at the time of setting and “A” for response data at the time of readout.
Readout request of year/month/date/time
STX
YMD
R
(Check sum)
Delimiter
Name
Data length
[byte]
Description
Remarks
Dominical year
4
“1980”–“2037” [year]
Month
2
“01”–“12” [month]
Day
2
“01”–“31” [day]
Hour
2
“00”–“23” [hour]
Minute
2
“00”–“59” [minute]
Second
2
“00”–“59” [second]
Reference
•
The setting changed by this command is saved without overwriting.
■
Era year: ERA
Sets era year.
Setting / Readout data of era year
STX
ERA
Sub
command
[Era year]
4-byte
(Check sum)
Delimiter
Sub command is “S” at the time of setting and “A” for response data at the time of readout.
Readout request of era year
STX
ERA
R
(Check sum)
Delimiter
Name
Data length
[byte]
Description
Remarks
Era year
4
“0001”–“9999” [year]
Reference
•
The setting changed by this command is saved without overwriting.
ME-LPMSZ-SR-9
Summary of Contents for LP-M Series
Page 8: ...1 Before External Control ME LPMSZ SR 9...
Page 16: ...2 Basics of Serial Communication RS 232 Ethernet ME LPMSZ SR 9...
Page 34: ...3 Communication Command and Function ME LPMSZ SR 9...
Page 165: ...Troubleshooting ME LPMSZ SR 9...
Page 186: ...Character Code Table ME LPMSZ SR 9...
Page 199: ...Index ME LPMSZ SR 9...
Page 202: ...202 MEMO No 9000 0063 59V ME LPMSZ SR 9...
Page 203: ...No 9000 0063 59V...
Page 204: ...Panasonic Industrial Devices SUNX Co Ltd 2013 2019 March 2019 9000 0063 59V...