122
■
Laser pumping: LSR
Controls the laser pumping ON/OFF.
Setting / Readout data of laser pumping
STX
LSR
Sub
command
[Laser pumping]
1-byte
(Check sum)
Delimiter
Sub command is “S” at the time of setting and “A” for response data at the time of readout.
Readout request of laser pumping
STX
LSR
R
(Check sum)
Delimiter
Name
Data length
[byte]
Description
Remarks
Laser pumping
1
“0”: Laser pumping OFF
“1”: Laser pumping ON
Reference
•
Control of laser pumping by this command is unavailable when the No. 2 DIP switch on the back surface of controller is
turned to OFF.
•
It takes about 20 seconds for LP-Mxxx/LP-Sxxx/LP-Zxxx type and about 15 seconds for LP-SxxxW type from turning
ON the laser pumping to completion of pumping.
■
Shutter: SHT
Controls the internal shutter opening/closing.
Setting of shutter
STX
SHT
S
[Shutter status]
1-byte
(Check sum)
Delimiter
Name
Data length
[byte]
Description
Remarks
Shutter status
1
“0”: Close
“1”: Open
Reference
•
Control of shutter by this command is unavailable when the No. 2 DIP switch on the back surface of controller is turned
to OFF.
•
Response data for abnormal receiving (NAK03) is returned when shutter open command is transmitted in shutter open
status.
•
If the shutter close command is transmitted during marking, the internal shutter is closed after the marking is completed.
ME-LPMSZ-SR-9
Summary of Contents for LP-M Series
Page 8: ...1 Before External Control ME LPMSZ SR 9...
Page 16: ...2 Basics of Serial Communication RS 232 Ethernet ME LPMSZ SR 9...
Page 34: ...3 Communication Command and Function ME LPMSZ SR 9...
Page 165: ...Troubleshooting ME LPMSZ SR 9...
Page 186: ...Character Code Table ME LPMSZ SR 9...
Page 199: ...Index ME LPMSZ SR 9...
Page 202: ...202 MEMO No 9000 0063 59V ME LPMSZ SR 9...
Page 203: ...No 9000 0063 59V...
Page 204: ...Panasonic Industrial Devices SUNX Co Ltd 2013 2019 March 2019 9000 0063 59V...