124
■
Marking status transmission permission: MST
Enables automatic response of marking result (e.g. normal end, and error occurrence, etc.) at the end of marking.
Setting / Readout data of marking status transmission permission
STX
MST
Sub
command
[Transmission permission/prohibition]
1-byte
(Check sum)
Delimiter
Sub command is “S” at the time of setting and “A” for response data at the time of readout.
Readout request of transmission permission/prohibition of response
STX
MST
R
(Check sum)
Delimiter
Name
Data length
[byte]
Description
Remarks
Transmission
permission/
prohibition
1
“0”: Transmission prohibited
“1”: Transmission permitted
Data transmission after setting marking status transmission permission
The status is transmitted if the marking failure occurs when marking is normally completed or when character string is set
outside the marking area transmission permission when receiving a marking trigger from the RS-232C after marking status
transmission permission is set.
STX
MST
A
[Status]
4-byte
(Check sum)
Delimiter
Name
Data length
[byte]
Description
Remarks
Status
4
“0000”: Marking is normally completed.
“E001”–“E999”: Error code at marking operation
The status after marking operation
is indicated.
Reference
•
When marking status function is used, set the transmission permission before every shifting to the remote mode.
•
When the remote mode is released, the marking status transmission is returned to the default transmission prohibition.
•
Refer to “Error Indication” (P.178) for the detail of the error code at marking operation.
•
The error code indicated by this command is for the LP-M/LP-S/LP-Z series, so differs from the error code for the LP-
F10/LP-F10W series.
ME-LPMSZ-SR-9
Summary of Contents for LP-M Series
Page 8: ...1 Before External Control ME LPMSZ SR 9...
Page 16: ...2 Basics of Serial Communication RS 232 Ethernet ME LPMSZ SR 9...
Page 34: ...3 Communication Command and Function ME LPMSZ SR 9...
Page 165: ...Troubleshooting ME LPMSZ SR 9...
Page 186: ...Character Code Table ME LPMSZ SR 9...
Page 199: ...Index ME LPMSZ SR 9...
Page 202: ...202 MEMO No 9000 0063 59V ME LPMSZ SR 9...
Page 203: ...No 9000 0063 59V...
Page 204: ...Panasonic Industrial Devices SUNX Co Ltd 2013 2019 March 2019 9000 0063 59V...