138
■
Bar code marking condition: BCF
Specifies the bar code marking condition.
Setting / Readout data of bar code marking condition
STX
BCF
Sub
command
[Bar code No.] [Bar code type] [Inversion] [Check character]
[Height] [Narrow element] [X position] [Y position] [Tilt angle]
[Quiet ratio] [Wide element] [Laser power cor.]
[Scan speed correction] [Laser pulse cycle correction]
50-byte (LP-F10 mode), 47-byte (LP-F10W mode)
(Check
sum)
Delimiter
Sub command is “S” at the time of setting and “A” for response data at the time of readout.
Readout request of bar code marking condition
STX
BCF
R
[Bar code No.]
1-byte
(Check sum)
Delimiter
Name
Data length
[byte]
Description
Remarks
Bar code No.
1
“0”–“3”
Bar code type
1
“0”: CODE39
“1”: ITF
Inversion
1
“0”: Do not invert
“1”: Invert
Check character
1
“0”: Absence
“1”: Presence
Bar code height
6
Model type*
Setting range [mm]
LP-Sxx0(W)
“001.00”–“090.00”
LP-Sxx5(W)
“001.00”–“160.00”
LP-Sxx2
“001.00”–“055.00”
LP-Mxx0/LP-Zxx0
“001.00”–“120.00”
LP-Mxx5
“001.00”–“220.00”
LP-Mxx6/LP-Zxx6
“001.00”–“330.00”
Narrow element
4
“0.05”–“1.00” [mm]
Indicates the width of narrow element
of bar and space. Set the larger value
than “Line width” in laser setting
screen.
X position
7
Model type*
Setting range [mm]
LP-Sxx0(W)
“-045.00”–“+045.00”
LP-Sxx5(W)
“-080.00”–“+080.00”
LP-Sxx2
“-027.50”–“+027.50”
LP-Mxx0/LP-Zxx0
“-060.00”–“+060.00”
LP-Mxx5
“-110.00”–“+110.00”
LP-Mxx6/LP-Zxx6
“-165.00”–“+165.00”
Specifies the center coordinate of the
code.
Y position
7
Tilt angle
6
“-180.0”–“+180.0” [°]
Quiet/
Narrow ratio
4
“00.0”–“20.0”
Ratio of quiet width to narrow element
width
Wide/
Narrow ratio
3
“1.8”–“3.4”
Ratio of wide element width to narrow
element width
ME-LPMSZ-SR-9
Summary of Contents for LP-M Series
Page 8: ...1 Before External Control ME LPMSZ SR 9...
Page 16: ...2 Basics of Serial Communication RS 232 Ethernet ME LPMSZ SR 9...
Page 34: ...3 Communication Command and Function ME LPMSZ SR 9...
Page 165: ...Troubleshooting ME LPMSZ SR 9...
Page 186: ...Character Code Table ME LPMSZ SR 9...
Page 199: ...Index ME LPMSZ SR 9...
Page 202: ...202 MEMO No 9000 0063 59V ME LPMSZ SR 9...
Page 203: ...No 9000 0063 59V...
Page 204: ...Panasonic Industrial Devices SUNX Co Ltd 2013 2019 March 2019 9000 0063 59V...