139
Name
Data length
[byte]
Description
Remarks
Laser power
correction
3
“000”–“200” [%]
•
The correction ratio is calculated
using the value set at the laser
condition as 100%.
•
Laser Pulse Cycle Correction can
be specified only in LP-F10 mode.
Scan speed
correction
3
“001”–“200” [%]
(Laser pulse
cycle correction)
(3)
“050”–“200” [%]
* For the detail of the model type, refer to “Target laser marker” (P.4).
Reference
•
The bar code No. 4 to 7 cannot be set and read out. (NAK09 is returned.)
•
Readout is available only when CODE39/ITF is set in the bar code type.
(When other bar code is set, NAK15 is returned.)
• In readout response, the digit of 1 μm or 0.01° is rounded down.
•
When the setting is performed using this command, the layer No. is “0”.
•
Setting with this command in the LP-F10W mode, the laser pulse cycle correction is set to 100%.
•
For LP-SxxxW type, the laser pulse cycle correction setting does not affect the marking. Also this setting is not saved in
the file.
ME-LPMSZ-SR-9
Summary of Contents for LP-M Series
Page 8: ...1 Before External Control ME LPMSZ SR 9...
Page 16: ...2 Basics of Serial Communication RS 232 Ethernet ME LPMSZ SR 9...
Page 34: ...3 Communication Command and Function ME LPMSZ SR 9...
Page 165: ...Troubleshooting ME LPMSZ SR 9...
Page 186: ...Character Code Table ME LPMSZ SR 9...
Page 199: ...Index ME LPMSZ SR 9...
Page 202: ...202 MEMO No 9000 0063 59V ME LPMSZ SR 9...
Page 203: ...No 9000 0063 59V...
Page 204: ...Panasonic Industrial Devices SUNX Co Ltd 2013 2019 March 2019 9000 0063 59V...