145
■
Data Matrix code pattern: DMP
Sets Data Matrix code module marking pattern.
Data Matrix code pattern setting
STX
DMP
Sub
command
[Data Matrix No.] [Quiet zone]
[Mark module] [Space module]
40-byte
(Check sum)
Delimiter
Sub command is “S” at the time of setting and “A” for response data at the time of readout.
Readout request of Data Matrix code pattern
STX
DMP
R
[Data Matrix No.]
1-byte
(Check sum)
Delimiter
Name
Data length
[byte]
Description
Remarks
Data Matrix No.
1
“0”–“3”
Quiet zone pattern
13
Refer to “Character Code Table” (P.186)
for the character code.
When the marking cannot be done,
set the character code to “0000”.
Specifies a character code (a pattern code)
to use for the quiet zone pattern.
“000”–“200”
“050”–“200”
“050”–“200”
(Specify “100” in LP-F10W mode.)
Specifies a correction value of laser and
scan speed when marking the quiet zone
pattern.
•
Laser Power Correction (3-byte)
•
Scan Speed Correction (3-byte)
•
Laser Pulse Cycle Correction (3-byte)
Mark module
pattern
13
Same as above
Specifies the character code to be used for
the mark module pattern and the correction
value to mark the mark module pattern.
Space module
pattern
13
Same as above
Specifies the character code to be used for
the space module pattern and the correction
value to mark the mark module pattern.
Reference
•
Setting with this command in the LP-F10W mode, the laser pulse cycle correction is set to 100%.
•
For LP-SxxxW type, the laser pulse cycle correction setting does not affect the marking. Also this setting is not saved in
the file.
ME-LPMSZ-SR-9
Summary of Contents for LP-M Series
Page 8: ...1 Before External Control ME LPMSZ SR 9...
Page 16: ...2 Basics of Serial Communication RS 232 Ethernet ME LPMSZ SR 9...
Page 34: ...3 Communication Command and Function ME LPMSZ SR 9...
Page 165: ...Troubleshooting ME LPMSZ SR 9...
Page 186: ...Character Code Table ME LPMSZ SR 9...
Page 199: ...Index ME LPMSZ SR 9...
Page 202: ...202 MEMO No 9000 0063 59V ME LPMSZ SR 9...
Page 203: ...No 9000 0063 59V...
Page 204: ...Panasonic Industrial Devices SUNX Co Ltd 2013 2019 March 2019 9000 0063 59V...