155
4.
For fine adjustment for all columns/fine adjustment for all rows/fine adjustment for column/fine adjustment
for row (data length: 18-byte)
Name
Data length
[byte]
Description
Remarks
List line
2
“00”–“99”
Fine adj. type
1
“3”: Fine adjustment for all columns
“4”: Fine adjustment for all rows
“5”: Fine adjustment for column
“6”: Fine adjustment for row
Target column
or row
3
“001”–“100”
Sets target column(s) or row(s) for fine
adjustment. In case of fine adjustment for
all columns/rows, the specified column/
row and all subsequent columns/rows will
be subject to fine adjustment.
Fine tune X
6
Model type*
Setting range [mm]
LP-Sxx0(W)
“-45.00”–“+45.00”
LP-Sxx5(W)
“-80.00”–“+80.00”
LP-Sxx2
“-27.50”–“+27.50”
LP-Mxx0 / LP-Zxx0
“-60.00”–“+60.00”
LP-Mxx5
“-99.99”–“+99.99”
LP-Mxx6/LP-Zxx6
“-99.99”–“+99.99”
Fine tune Y
6
* For the detail of the model type, refer to “Target laser marker” (P.4).
Reference
•
The readout of the list line 100 and after cannot be set. (NAK09 is returned.)
•
When the setting is performed using this command, the rotation angle and laser power adjustment become “0”.
• In readout response, the digit of 1 μm is rounded down.
ME-LPMSZ-SR-9
Summary of Contents for LP-M Series
Page 8: ...1 Before External Control ME LPMSZ SR 9...
Page 16: ...2 Basics of Serial Communication RS 232 Ethernet ME LPMSZ SR 9...
Page 34: ...3 Communication Command and Function ME LPMSZ SR 9...
Page 165: ...Troubleshooting ME LPMSZ SR 9...
Page 186: ...Character Code Table ME LPMSZ SR 9...
Page 199: ...Index ME LPMSZ SR 9...
Page 202: ...202 MEMO No 9000 0063 59V ME LPMSZ SR 9...
Page 203: ...No 9000 0063 59V...
Page 204: ...Panasonic Industrial Devices SUNX Co Ltd 2013 2019 March 2019 9000 0063 59V...