163
■
Laser check radiation: SPT
Controls “Laser check radiation” for laser radiation at the center of the marking area.
Setting of laser check
STX
SPT
S
[Laser check radiation]
1-byte
(Check sum)
Delimiter
Name
Data length
[byte]
Description
Remarks
Laser check
radiation
1
“0”: Stop radiation
“1”: Start radiation
“2”: Stop radiation temporarily
•
The internal shutter is automatically opened
and closed at the time of start and stop of
radiation.
•
“Stop radiation temporarily” refers to the status
stopping radiation with the shutter opened. Use
this state only when restarting radiation in a
while.
•
To restart the radiation after sending “2” (Stop
radiation temporarily), send “1” without closing
the shutter.
Reference
•
This command is available only when the DIP switch No. 2 on the rear side of the controller is ON.
•
You can start the laser radiation only when the laser pumping is completed and the shutter is closed or the “command
reception mode ON” is set by Command reception permission (MKM) command.
•
The laser is radiated at the center position.
•
The laser power can be changed by setting the laser condition.
•
Do not control other operation or setting with “Stop radiation temporarily” status. Laser radiation should be ended with
“Stop radiation” status.
•
Do not execute any other operation during the laser radiation.
■
Year/Month/Date/Time: YMD
Sets year, month, date, time for system.
Setting / Readout data of year/month/date/time
STX
YMD
Sub
command
[Dominical year] [Month] [Day] [Hour] [Minute] [Second]
14-byte
(Check sum)
Delimiter
Sub command is “S” at the time of setting and “A” for response data at the time of readout.
Readout request of year/month/date/time
STX
YMD
R
(Check sum)
Delimiter
Name
Data length
[byte]
Description
Remarks
Dominical year
4
“1980”–“2037” [year]
Month
2
“01”–“12” [month]
Day
2
“01”–“31” [day]
Hour
2
“00”–“23” [hour]
Minute
2
“00”–“59” [minute]
Second
2
“00”–“59” [second]
Reference
•
The setting changed by this command is saved without overwriting.
ME-LPMSZ-SR-9
Summary of Contents for LP-M Series
Page 8: ...1 Before External Control ME LPMSZ SR 9...
Page 16: ...2 Basics of Serial Communication RS 232 Ethernet ME LPMSZ SR 9...
Page 34: ...3 Communication Command and Function ME LPMSZ SR 9...
Page 165: ...Troubleshooting ME LPMSZ SR 9...
Page 186: ...Character Code Table ME LPMSZ SR 9...
Page 199: ...Index ME LPMSZ SR 9...
Page 202: ...202 MEMO No 9000 0063 59V ME LPMSZ SR 9...
Page 203: ...No 9000 0063 59V...
Page 204: ...Panasonic Industrial Devices SUNX Co Ltd 2013 2019 March 2019 9000 0063 59V...