183
ERROR
CODE
Error description
Measures
E630
Too much quantity of Step and Repeat marking.
Reduce numbers of characters to be marked.
(Max.: 4000)
E640
Invalid function for combining with flying object.
With the marking to the moving object, do not use
the following functions.
•
Step & Repeat
•
Reset at date update function
•
Arbitrary point radiation
•
Overwrite function
With the equidistant marking to flying object, do
not use the following functions.
•
Rank
•
External offset
•
Serial data marking
Release flying object marking function with trigger
setting.
E650
Invalid setting of processing element.
Set the distance between start and end points of
the arc smaller than double of radius.
E651
Too short line segment of processing element.
Set the larger value to the length of the line than
width of the line.
E660
Cannot convert dxf file.
• Read the DXF file again.
• Save the DXF file with DXF-R12J, R13J or R14
format.
•
Delete the entities which are not supported by
laser marker in the DXF file.
E670
Existed 3D marking data outside of marking area.
•
Adjust the setting of 3D work with overall (layer)
condition.
•
Adjust the setting of character, logo, and bar
code, etc. for 3D work.
E672
Existed invalid 3D marking data.
E674
Existed marking data with its Z position outside of
marking area.
•
Adjust the setting of Z offset value with
following overall (general) condition.
•
Adjust the setting of Z offset value with
following system offset.
E675
Invalid setting of layer condition.
Adjust the setting of 3D work with overall (layer)
condition.
E676
Invalid function for combining with 3D marking.
With the 3D marking, do not use the following
functions.
•
Step & Repeat
•
External offset
•
Processing conditions
•
Arbitrary point radiation
Release check of 3D check box with overall
(general) condition.
E677
Invalid encoder setting of flying object for combining with
3D marking.
Release check of 3D check box with overall
(general) condition. Or, set the encoder signal
with the trigger condition.
ME-LPMSZ-SR-9
Summary of Contents for LP-M Series
Page 8: ...1 Before External Control ME LPMSZ SR 9...
Page 16: ...2 Basics of Serial Communication RS 232 Ethernet ME LPMSZ SR 9...
Page 34: ...3 Communication Command and Function ME LPMSZ SR 9...
Page 165: ...Troubleshooting ME LPMSZ SR 9...
Page 186: ...Character Code Table ME LPMSZ SR 9...
Page 199: ...Index ME LPMSZ SR 9...
Page 202: ...202 MEMO No 9000 0063 59V ME LPMSZ SR 9...
Page 203: ...No 9000 0063 59V...
Page 204: ...Panasonic Industrial Devices SUNX Co Ltd 2013 2019 March 2019 9000 0063 59V...