25
■
Control sample 1-1 : Changing the marking characters
Reference
•
Other than STR and MCS command, SIN command can be used for changing character of marking command. SIN
command is recommended to use in case faster processing is required.
•
For LP-Mxxx-S type, open the laser gate to turn ON the ready signal.
Laser gate can be controlled with any timing regardless of the command sequence by the external signal input.
Change the character
to be marked
1. Laser pumping (ON)
LSR command
Remote mode ON
Remote mode OFF
2. Marking character string setting
MCS command or STR command
3. Shutter setting (open)
SHT command
4. Status request
STS command
5. Marking trigger
MRK command
6. Command reception mode ON
MKM command
7. Marking character string setting
MCS command or STR command
8. Command reception mode OFF
MKM command
9. Shutter setting (close)
SHT command
10. Laser pumping (OFF)
LSR command
Send STS command
again after a while.
* To memorize the last marked
character into the laser marker,
save it with “File Overwriting
Registration (FOR)”.
Send the character
to be marked.
“READY”: ON
Yes
To finish the
marking
Change the character.
Mark the same
character.
No.
ME-LPMSZ-SR-9
Summary of Contents for LP-M Series
Page 8: ...1 Before External Control ME LPMSZ SR 9...
Page 16: ...2 Basics of Serial Communication RS 232 Ethernet ME LPMSZ SR 9...
Page 34: ...3 Communication Command and Function ME LPMSZ SR 9...
Page 165: ...Troubleshooting ME LPMSZ SR 9...
Page 186: ...Character Code Table ME LPMSZ SR 9...
Page 199: ...Index ME LPMSZ SR 9...
Page 202: ...202 MEMO No 9000 0063 59V ME LPMSZ SR 9...
Page 203: ...No 9000 0063 59V...
Page 204: ...Panasonic Industrial Devices SUNX Co Ltd 2013 2019 March 2019 9000 0063 59V...