26
■
Control sample 1-2: Changing the marking characters for each marking
Reference
•
For using this command, set “serial data” of function characters at setting screen beforehand.
•
When using this function (serial data), transmit this command by every marking. Otherwise it does not become marking
ready condition, and marking is not available.
•
Only when the internal shutter is opened during the remote mode, the serial data can be transmitted to the laser marker.
•
When transmit this command without any data, marking ready become ON, then nothing to be marked with serial data
input.
•
For resetting the data, set the “reception mode ON” for command reception permission (MKM command) or close the
shutter.
•
For LP-Mxxx-S type, open the laser gate to turn ON the ready signal.
Laser gate can be controlled with any timing regardless of the command sequence by the external signal input.
“READY”: OFF
1. Laser pumping (ON)
LSR command
Remote mode ON
Remote mode OFF
2.
Select file No.
FNO command
3. Shutter setting (open)
SHT command
4. Serial data input
SIN command
5. Status request
STS command
6. Marking trigger
MRK command
7. Serial data input
SIN command
8. Shutter setting (close)
SHT command
9. Laser pumping (OFF)
LSR command
* “READY” will turn ON after the SIN command reception.
* Before sending SIN data, keep 20 sec. (LP-Mxxx / LP-Sxxx / LP-Zxxx) or 15 sec. (LP-SxxxW)
after turning ON the laser pumping, and 1 sec. after the opening shutter.
Send STS command
again after a while.
Select the file set “Command (SIN)
specified character”
“READY”: ON
Yes
To finish the
marking
Change the character.
No.
Send the character data to be marked.
ME-LPMSZ-SR-9
Summary of Contents for LP-M Series
Page 8: ...1 Before External Control ME LPMSZ SR 9...
Page 16: ...2 Basics of Serial Communication RS 232 Ethernet ME LPMSZ SR 9...
Page 34: ...3 Communication Command and Function ME LPMSZ SR 9...
Page 165: ...Troubleshooting ME LPMSZ SR 9...
Page 186: ...Character Code Table ME LPMSZ SR 9...
Page 199: ...Index ME LPMSZ SR 9...
Page 202: ...202 MEMO No 9000 0063 59V ME LPMSZ SR 9...
Page 203: ...No 9000 0063 59V...
Page 204: ...Panasonic Industrial Devices SUNX Co Ltd 2013 2019 March 2019 9000 0063 59V...