27
■ Control sample 2 : Changing the marking files
Reference
•
For LP-Mxxx-S type, open the laser gate to turn ON the ready signal.
Laser gate can be controlled with any timing regardless of the command sequence by the external signal input.
Change the file
to be marked
1. Laser pumping (ON)
LSR command
Remote mode ON
Remote mode OFF
2.
File switching (File No. specified)
FNO
command
3. Shutter setting (open)
SHT command
4. Status request
STS command
7. Shutter setting (close)
SHT command
8. Laser pumping (OFF)
LSR command
5. Marking trigger
MRK command
6. Change File No.
FNO command
Send STS command