Timing chart for serial data marking
The timing chart for the command for serial data input (SIN) is shown below.
%01:S0, %01:S1 (example when serial data number 0 and 1 are set)
T2
T1
OFF
ON
ON
ON
ON
OFF
OFF
OFF
ON
OFF
SINS00
ACK
ACK
ACK
ACK
SINS01
SINS00
SINS01
LASER IN
SHUTTER
CONTROL
INPUT
TRIG. IN
READY
MARKING
Command data
Response data
(Open)
(Close)
Item
Time
Remarks
T1
1 second or more
SIN command cannot be sent until the shutter opens.
The shutter opens approx. 1 second after the shutter open input.
T2
0 ms or more
After confirming the marking output is turned ON, the next SIN command data can be sent.
Reference
•
The command for serial data input (SIN) can be transmitted to the laser marker only under remote mode, and when the
internal shutter is opened (“Reception mode ON” is not set for command reception mode (MKM command)).
•
Whenever marking is performed, data of all set serial data function numbers must be transmitted.
•
For LP-Mxxx-S type, open the laser gate to turn ON the ready signal.
Laser gate can be controlled with any timing regardless of the command sequence by the external signal input.
ME-LPMSZ-SR-9
Summary of Contents for LP-M Series
Page 8: ...1 Before External Control ME LPMSZ SR 9...
Page 16: ...2 Basics of Serial Communication RS 232 Ethernet ME LPMSZ SR 9...
Page 34: ...3 Communication Command and Function ME LPMSZ SR 9...
Page 165: ...Troubleshooting ME LPMSZ SR 9...
Page 186: ...Character Code Table ME LPMSZ SR 9...
Page 199: ...Index ME LPMSZ SR 9...
Page 202: ...202 MEMO No 9000 0063 59V ME LPMSZ SR 9...
Page 203: ...No 9000 0063 59V...
Page 204: ...Panasonic Industrial Devices SUNX Co Ltd 2013 2019 March 2019 9000 0063 59V...