Counter: CNT
Sets the counter conditions.
Setting / Readout data of counter condition
STX
CNT
Sub
command
[Counter No.] [Current value] [Initial value] [End value]
[Step] [Count source] [Flag reset]
27-byte
(Check sum)
Delimiter
Sub command is “S” at the time of setting and “A” for response data at the time of readout.
Readout request of counter condition
STX
CNT
R
[Counter No.]
1-byte
(Check sum)
Delimiter
Name
Data length
[byte]
Description
Remarks
Counter No.
1
“0”–“7”
“4”–“7”: common counter
Current value
6
“000000”–“999999”
No minus number.
Initial value
6
“000000”–“999999”
End value
6
“000000”–“999999”
Step
6
“000000”–“999999”
Count source
1
“0”: Counter 0
“1”: Counter 1
“2”: Counter 2
“3”: Counter 3
“4”: Counter 4
“5”: Counter 5
“6”: Counter 6
“7”: Counter 7
“8”: Trigger input
Flag reset
1
“0”: Reset OFF at re-dating
“1”: Reset ON at re-dating
When the marking on the flying
object is valid, set “0”.
Reference
• When marking on the flying object is valid, counter reset at re-dating timing cannot be used.
ME-LPMSZ-SR-9
Summary of Contents for LP-M Series
Page 8: ...1 Before External Control ME LPMSZ SR 9...
Page 16: ...2 Basics of Serial Communication RS 232 Ethernet ME LPMSZ SR 9...
Page 34: ...3 Communication Command and Function ME LPMSZ SR 9...
Page 165: ...Troubleshooting ME LPMSZ SR 9...
Page 186: ...Character Code Table ME LPMSZ SR 9...
Page 199: ...Index ME LPMSZ SR 9...
Page 202: ...202 MEMO No 9000 0063 59V ME LPMSZ SR 9...
Page 203: ...No 9000 0063 59V...
Page 204: ...Panasonic Industrial Devices SUNX Co Ltd 2013 2019 March 2019 9000 0063 59V...