55
■ Bar code marking data (ASCII code specified) : BCS
Sets character string to be encoded as a bar code or 2D code by ASCII code. For alphanumeric and symbols only.
Setting / Readout data of bar code marking data
STX
BCS
Sub
command
[Bar code No.] [Line No.] [Bar code data]
Max. 34-byte
(Check sum)
Delimiter
Sub command is “S” at the time of setting and “A” for response data at the time of readout.
Readout request of bar code marking data
STX
BCS
R
[Bar code No.] [Line No.]
Max. 4-byte
(Check sum)
Delimiter
Name
Data length
[byte]
Description
Remarks
Bar code No.
2
“00”–“15”
Line No.
1 or 2
1D code: “1”–“2”
2D code: “1”–“9”
2D part of Composite code: “01”–“09”
Specifies the line for data setting.
Bar code data
Max. 30
ASCII code characters within the range
from 20 (HEX) to 7E (HEX).
(Functional characters should not be
included.)
FNC1 can be entered at 1D (HEX).
Specifies the character setting in the
specified line.
Specify the data length with 0-byte in order
to delete the character string.
Reference
•
When setting bar code marking data in multiple lines, data in each line are jointed in the order of line numbers and they
are coded as the data in one line. (No line break is inserted for each line.)
•
When setting bar code marking data in multiple lines, the total input data should be 255 characters or less.
•
If readout data includes function characters (such as “%SFT:0”), the setting character (“%SFT:0”) is read out, but
characters to be actually marked are not.
•
If readout data includes characters that cannot be expressed in ASCII code such as Katakana and Kanji (Shift-JIS Code
Specified), only these 2-byte characters are read out in shift-JIS code. In this case, the maximum readout data will be
34-byte or more.
•
Use the BBS command or BRS command when bar code data includes a control code.
•
In the case that “GS1 Data Matrix” is selected as bar code type in bar code condition setting, the separator of variable
length AI data is inputted at GS (1D (HEX)) in this command. The separator is coded as “GS”.
•
For CODE128 (GS1-128), GS1 DataBar Expanded, and 2D side of composite codes, the separator of variable length AI
data “FNC1” can be input by using GS (1D (HEX)).
ME-LPMSZ-SR-9
Summary of Contents for LP-M Series
Page 8: ...1 Before External Control ME LPMSZ SR 9...
Page 16: ...2 Basics of Serial Communication RS 232 Ethernet ME LPMSZ SR 9...
Page 34: ...3 Communication Command and Function ME LPMSZ SR 9...
Page 165: ...Troubleshooting ME LPMSZ SR 9...
Page 186: ...Character Code Table ME LPMSZ SR 9...
Page 199: ...Index ME LPMSZ SR 9...
Page 202: ...202 MEMO No 9000 0063 59V ME LPMSZ SR 9...
Page 203: ...No 9000 0063 59V...
Page 204: ...Panasonic Industrial Devices SUNX Co Ltd 2013 2019 March 2019 9000 0063 59V...