■ Bar code marking data (ASCII code specified) : BBS
Sets character string to be encoded as a bar code or 2D code by ASCII code. For alphanumeric, symbols and specified
control codes (EOT/FS/GS/RS/US).
Setting / Readout data of bar code marking data
STX
BBS
Sub
command
[Bar code No.] [Line No.] [Bar code data]
Max. 34-byte
(Check sum)
Delimiter
Sub command is “S” at the time of setting and “A” for response data at the time of readout.
Readout request of bar code marking data
STX
BBS
R
[Bar code No.] [Line No.]
Max. 4-byte
(Check sum)
Delimiter
Name
Data length
[byte]
Description
Remarks
Bar code No.
2
“00”–“15”
Line No.
1 or 2
1D code: “1”–“2”
2D code: “1”–“9”
2D part of Composite code: “01”–“09”
Specifies the line for data setting.
Bar code data
Max. 30
ASCII code characters within the range
from 04 (HEX) and 1C (HEX) to 7E (HEX).
(Functional characters should not be
included.)
Specifies the character setting in the
specified line.
Specify the data length with 0-byte in
order to delete the character string.
Reference
•
When setting bar code marking data in multiple lines, data in each line are jointed in the order of line numbers and they
are coded as the data in one line. (No line break is inserted for each line.)
•
When setting bar code marking data in multiple lines, the total input data should be 255 characters or less.
•
If readout data includes function characters (such as “%SFT:0”), the setting character (“%SFT:0”) is read out, but
characters to be actually marked are not.
•
If readout data includes characters that cannot be expressed in ASCII code such as Katakana and Kanji (Shift-JIS Code
Specified), only these 2-byte characters are read out in shift-JIS code. In this case, the maximum readout data will be
34-byte or more.
•
To input the control codes in the barcode/2D code strings, set the code data as follows:
•
The following control codes EOT, FS, GS, RS, or US you can set by using ASCII code.
Control code
EOT
FS
GS
RS
US
ASCII code (HEX)
04
1C
1D
1E
1F
•
To include the control codes other than EOT, FS, GS, RS, or US in the strings, set the all control codes with BRS
command by using these 2-byte alternate codes instead of ASCII code.
•
In the case that “GS1 Data Matrix” is selected as bar code type in bar code condition setting, the separator of
variable length AI data is inputted at GS (1D (HEX)) in this command. The separator is coded as “GS”.
•
For codes other than GS1 Data Matrix, the separator of variable length AI data “FNC1” cannot be set by this
command. Use BCS command or BRS command to set “FNC1”.
ME-LPMSZ-SR-9
Summary of Contents for LP-M Series
Page 8: ...1 Before External Control ME LPMSZ SR 9...
Page 16: ...2 Basics of Serial Communication RS 232 Ethernet ME LPMSZ SR 9...
Page 34: ...3 Communication Command and Function ME LPMSZ SR 9...
Page 165: ...Troubleshooting ME LPMSZ SR 9...
Page 186: ...Character Code Table ME LPMSZ SR 9...
Page 199: ...Index ME LPMSZ SR 9...
Page 202: ...202 MEMO No 9000 0063 59V ME LPMSZ SR 9...
Page 203: ...No 9000 0063 59V...
Page 204: ...Panasonic Industrial Devices SUNX Co Ltd 2013 2019 March 2019 9000 0063 59V...