68
Name
Data length
[byte]
Description
Remarks
Laser power
correction
3
“000”–“999” [%]
•
The correction ratio is calculated using
the value set at the laser condition as
100%.
•
With LP-SxxxW type, nothing
should be input in Laser Pulse Cycle
Correction.
Scan speed
correction
3
“001”–“999” [%]
(Laser
pulse cycle
correction)
(3)
“001”–“999” [%]
Linefeed
(1)
“0”: Without linefeed
“1”: With linefeed
(Only for 2D side or GS1 Data Matrix)
Specifies the linefeed at marking human
readable text. When the linefeed is valid,
the line break part conforms with the line
number of the bar code data.
Line interval
(7)
Model type*
Setting range [mm]
LP-Sxx0(W)
“000.000”–“090.000”
LP-Sxx5(W)
“000.000”–“160.000”
LP-Sxx2
“000.000”–“055.000”
LP-Mxx0/LP-Zxx0
“000.000”–“120.000”
LP-Mxx5
“000.000”–“220.000”
LP-Mxx6/LP-Zxx6
“000.000”–“330.000”
(Only for marking of Composite on a new
line on 2D side.)
Specifies the line interval at marking
human readable text on a new line.
* For the detail of the model type, refer to “Target laser marker” (P.4).
2. When the barcode type is EAN / UPC (including when EAN / UPC is 1D part of the composite code)
Data length: max. 19-byte
Name
Data length
[byte]
Description
Remarks
Bar code No.
2
“00”–“15”
Setting
section
1
“1”: EAN/UPC or 1D side of Composite code
“2”: 2D side of Composite code
When the code type is other than the
Composite code, select “1”.
Font No.
2
“01”–“10”
Bold line
width
5
Model type*
Setting range [mm]
LP-Sxx0(W)/LP-Sxx2/
LP-Mxx0/LP-Zxx0
“0.000”–“2.000”
LP-Sxx5(W)//LP-Mxx5/
LP-Mxx6/LP-Zxx6
“0.000”–“4.000”
Laser power
correction
3
“000”–“999” [%]
•
The correction ratio is calculated using
the value set at the laser condition as
100%.
•
With LP-SxxxW type, nothing should be
input in Laser Pulse Cycle Correction.
Scan speed
correction
3
“001”–“999” [%]
(Laser
pulse cycle
correction)
(3)
“001”–“999” [%]
* For the detail of the model type, refer to “Target laser marker” (P.4).
ME-LPMSZ-SR-9
Summary of Contents for LP-M Series
Page 8: ...1 Before External Control ME LPMSZ SR 9...
Page 16: ...2 Basics of Serial Communication RS 232 Ethernet ME LPMSZ SR 9...
Page 34: ...3 Communication Command and Function ME LPMSZ SR 9...
Page 165: ...Troubleshooting ME LPMSZ SR 9...
Page 186: ...Character Code Table ME LPMSZ SR 9...
Page 199: ...Index ME LPMSZ SR 9...
Page 202: ...202 MEMO No 9000 0063 59V ME LPMSZ SR 9...
Page 203: ...No 9000 0063 59V...
Page 204: ...Panasonic Industrial Devices SUNX Co Ltd 2013 2019 March 2019 9000 0063 59V...