71
■ Logo file: CDF
Sets the logo file.
Setting / Readout data of logo marking function
STX
CDF
Sub
command
[Log No.] [Log file name]
Variable length
(Check sum)
Delimiter
Sub command is “S” at the time of setting and “A” for response data at the time of readout.
Readout request of logo marking function
STX
CDF
R
[Logo No.]
2-byte
(Check sum)
Delimiter
Name
Data length
[byte]
Description
Remarks
Logo No.
2
“00”–“99”
Logo file name
Variable
length
The long file name can be specified.
Except the extended characters,
entry of up to 10 Shift-JIS characters
or 20 ASCII code characters is
recommended.
The logo file name corresponding to the
specified number is indicated.
The logo file setting will be deleted when no
file name is specified in this command.
• For VEC file, the extension can be
omitted (in this case, the response has an
extension.)
When the file name is “ABCD.VEC”:
“ABCD” or “ABCD.VEC”
• For a DXF file, an extension is required.
When the file name is “ABCD.DXF”:
“ABCD.DXF”.
Reference
• In the case of specifying logo file in VEC format, apply CDC command for setting logo condition, and in the case of
specifying logo file in DXF format, apply CDD command for setting logo condition.
•
If readout data includes characters that cannot be expressed in ASCII code such as Katakana and Kanji (2-byte
character), these 2-byte characters are read out in shift-JIS code.
ME-LPMSZ-SR-9
Summary of Contents for LP-M Series
Page 8: ...1 Before External Control ME LPMSZ SR 9...
Page 16: ...2 Basics of Serial Communication RS 232 Ethernet ME LPMSZ SR 9...
Page 34: ...3 Communication Command and Function ME LPMSZ SR 9...
Page 165: ...Troubleshooting ME LPMSZ SR 9...
Page 186: ...Character Code Table ME LPMSZ SR 9...
Page 199: ...Index ME LPMSZ SR 9...
Page 202: ...202 MEMO No 9000 0063 59V ME LPMSZ SR 9...
Page 203: ...No 9000 0063 59V...
Page 204: ...Panasonic Industrial Devices SUNX Co Ltd 2013 2019 March 2019 9000 0063 59V...