72
■
VEC logo conditions: CDC
Sets the marking condition of VEC (work shape converted for laser marker) logo file.
Setting / Readout data of VEC logo condition
STX
CDC
Sub
command
[Logo No.] [Layer No.] [X scale] [Y scale] [X position]
[Y position] [Rotation angle] [Laser power correction]
[Scan speed correction] [Laser pulse cycle correction]
52-byte (LP-Mxxx / LP-Sxxx / LP-Zxxx), 49-byte (LP-SxxxW)
(Check
sum)
Delimiter
Sub command is “S” at the time of setting and “A” for response data at the time of readout.
Readout request of VEC logo condition
STX
CDC
R
[Logo No.]
2-byte
(Check sum)
Delimiter
Name
Data length
[byte]
Content
Remarks
Logo No.
2
“00”–“99”
Layer No.
2
“00”–“15”
X scale
8
“0010.000”–“1000.000” [%]
Y scale
8
X position
8
“-330.000”–“+330.000” [mm]
Specifies the origin coordinate of the logo.
Y position
8
Rotation angle
7
“-180.00”–“+180.00” [°]
The angle of rotation centering on the origin
position of logo file, is indicated.
Laser power
correction
3
“000”–“999” [%]
•
The correction ratio is calculated using the
value set at the laser condition as 100%.
•
With LP-SxxxW type, nothing should be input
in Laser Pulse Cycle Correction.
Scan speed
correction
3
“001”–“999” [%]
(Laser pulse cycle
correction)
(3)
“001”–“999” [%]
Reference
• Use the CDD Command for the condition setting of DXF file. The common parameters with VEC and DXF files are
changed by either CDC/CDD command.
ME-LPMSZ-SR-9
Summary of Contents for LP-M Series
Page 8: ...1 Before External Control ME LPMSZ SR 9...
Page 16: ...2 Basics of Serial Communication RS 232 Ethernet ME LPMSZ SR 9...
Page 34: ...3 Communication Command and Function ME LPMSZ SR 9...
Page 165: ...Troubleshooting ME LPMSZ SR 9...
Page 186: ...Character Code Table ME LPMSZ SR 9...
Page 199: ...Index ME LPMSZ SR 9...
Page 202: ...202 MEMO No 9000 0063 59V ME LPMSZ SR 9...
Page 203: ...No 9000 0063 59V...
Page 204: ...Panasonic Industrial Devices SUNX Co Ltd 2013 2019 March 2019 9000 0063 59V...