81
■
Character condition (Shortened form) : SPC
Sets the condition for marking character string per line.
(X/Y coordinates and laser power correction ratio only)
Setting / Readout data of character condition (shortened form)
STX
SPC
Sub
command
[Character condition No.] [X position] [Y position]
[Laser power correction]
21-byte
(Check sum)
Delimiter
Sub command is “S” at the time of setting and “A” for response data at the time of readout.
Readout request of character condition (shortened form)
STX
SPC
R
[Character condition No.]
2-byte
(Check sum)
Delimiter
Name
Data length
[byte]
Description
Remarks
Character
condition No.
2
“01”–“99”
X position
8
When the marking form is other than sector
marking
Model type*
Setting range [mm]
LP-Sxx0(W)
“-045.000”–“+045.000”
LP-Sxx5(W)
“-080.000”–“+080.000”
LP-Sxx2
“-027.500”–“+027.500”
LP-Mxx0/LP-Zxx0 “-060.000”–“+060.000”
LP-Mxx5
“-110.000”–“+110.000”
LP-Mxx6/LP-Zxx6 “-165.000”–“+165.000”
When the marking form is other than sector
marking :
“-999.999”–“+999.999” [mm]
Sets the coordinate (X/Y) of the
character.
The base position of the coordinate
varies from “alignment” setting:
Left: lower left of the first character
Center: the center of the string
Right: lower right of the last character.
Y position
8
Laser power
correction
3
“000”–“999” [%]
The correction ratio is calculated using
the value set at the laser condition as
100%.
* For the detail of the model type, refer to “Target laser marker” (P.4).
ME-LPMSZ-SR-9
Summary of Contents for LP-M Series
Page 8: ...1 Before External Control ME LPMSZ SR 9...
Page 16: ...2 Basics of Serial Communication RS 232 Ethernet ME LPMSZ SR 9...
Page 34: ...3 Communication Command and Function ME LPMSZ SR 9...
Page 165: ...Troubleshooting ME LPMSZ SR 9...
Page 186: ...Character Code Table ME LPMSZ SR 9...
Page 199: ...Index ME LPMSZ SR 9...
Page 202: ...202 MEMO No 9000 0063 59V ME LPMSZ SR 9...
Page 203: ...No 9000 0063 59V...
Page 204: ...Panasonic Industrial Devices SUNX Co Ltd 2013 2019 March 2019 9000 0063 59V...